briCrntPMOPRAvgValidity
BTI-7000-MIB ·
.1.3.6.1.4.1.18070.2.2.1.6.38.1.30
Object
column
BTI-TC-MIBPMValidity
Indicates the validity of the provided average optical power received value.
Context
- MIB
- BTI-7000-MIB
- OID
.1.3.6.1.4.1.18070.2.2.1.6.38.1.30- Type
- column
- Access
- readonly
- Status
- current
- Parent
- briCrntPMEntry
- Table
- briCrntPMTable
- Siblings
- 42
Syntax
BTI-TC-MIBPMValidity
- Source
- BTI-TC-MIBPMValidity
- Base type
Enumeration
Values & Constraints
Type Values
1 | complete |
2 | notAvailable |
3 | partialCount |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| briCrntPMShelfIdx The number of the shelf on which the BRI facility targeted for
PMs is provisioned. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.1 |
| briCrntPMOPTValidity Indicates the validity of the provided optical power
transmitted value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.38.1.10 |
| briCrntPMTempValue The temperature measured on the BRI facility port. | column | degrees Celsius Integer32 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.11 |
| briCrntPMTempTimeStamp The date and time stamp of the temperature value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.38.1.12 |
| briCrntPMTempValidity Indicates the validity of the provided temperature value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.38.1.13 |
| briCrntPMSupplyVoltageValue The supply voltage measured on the BRI facility port. | column | mVolts/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.14 |
| briCrntPMSupplyVoltageTimeStamp The date and time stamp of the supply voltage value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.38.1.15 |
| briCrntPMSupplyVoltageValidity Indicates the validity of the provided supply voltage value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.38.1.16 |
| briCrntPMLBCValue The laser bias current measured on the BRI facility port. | column | mAmp Integer32 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.17 |
| briCrntPMLBCTimeStamp The date and time stamp of the laser bias current value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.38.1.18 |
| briCrntPMLBCValidity Indicates the validity of the provided laser bias current
value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.38.1.19 |
| briCrntPMSlotIdx The number of the slot within which the BRI facility targeted
for PMs is provisioned. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.2 |
| briCrntPMOPRMinValue The minimum optical power received on the input of the transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.20 |
| briCrntPMOPRMinTimeStamp The date and time stamp of the minimum optical power received value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.38.1.21 |
| briCrntPMOPRMinValidity Indicates the validity of the provided minimum optical power received
value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.38.1.22 |
| briCrntPMOPRMinInitialize Used to initialize the value of the briCrntPMOPRMinValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.38.1.23 |
| briCrntPMOPRMaxValue The maximum optical power received on the input of the transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.24 |
| briCrntPMOPRMaxTimeStamp The date and time stamp of the maximum optical power received value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.38.1.25 |
| briCrntPMOPRMaxValidity Indicates the validity of the provided maximum optical power received
value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.38.1.26 |
| briCrntPMOPRMaxInitialize Used to initialize the value of the briCrntPMOPRMaxValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.38.1.27 |
| briCrntPMOPRAvgValue The average optical power received on the input of the transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.28 |
| briCrntPMOPRAvgTimeStamp The date and time stamp of the average optical power received value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.38.1.29 |
| briCrntPMPortIdx The number of the port on the circuit pack on which the BRI
facility targeted for PMs is provisioned. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.3 |
| briCrntPMOPRAvgInitialize Used to initialize the value of the briCrntPMOPRAvgValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.38.1.31 |
| briCrntPMOPTMinValue The minimum optical power transmitted at the output of the
transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.32 |
| briCrntPMOPTMinTimeStamp The date and time stamp of the minimum optical power transmitted
value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.38.1.33 |
| briCrntPMOPTMinValidity Indicates the validity of the provided minimum optical power
transmitted value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.38.1.34 |
| briCrntPMOPTMinInitialize Used to initialize the value of the briCrntPMOPTMinValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.38.1.35 |
| briCrntPMOPTMaxValue The maximum optical power transmitted at the output of the
transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.36 |
| briCrntPMOPTMaxTimeStamp The date and time stamp of the maximum optical power transmitted
value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.38.1.37 |
| briCrntPMOPTMaxValidity Indicates the validity of the provided maximum optical power
transmitted value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.38.1.38 |
| briCrntPMOPTMaxInitialize Used to initialize the value of the briCrntPMOPTMaxValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.38.1.39 |
| briCrntPMIntervalTypeIdx The type of BRI bin according to interval length. | column | BTI-TC-MIBPMIntervalType | .1.3.6.1.4.1.18070.2.2.1.6.38.1.4 |
| briCrntPMOPTAvgValue The average optical power transmitted at the output of the
transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.40 |
| briCrntPMOPTAvgTimeStamp The date and time stamp of the average optical power transmitted
value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.38.1.41 |
| briCrntPMOPTAvgValidity Indicates the validity of the provided average optical power
transmitted value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.38.1.42 |
| briCrntPMOPTAvgInitialize Used to initialize the value of the briCrntPMOPTAvgValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.38.1.43 |
| briCrntPMOPRValue The optical power received on the input of the BRI facility
port. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.5 |
| briCrntPMOPRTimeStamp The date and time stamp of the optical power received value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.38.1.6 |
| briCrntPMOPRValidity Indicates the validity of the provided optical power received
value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.38.1.7 |
| briCrntPMOPTValue The optical power transmitted at the output of the BRI facility
port. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.38.1.8 |
| briCrntPMOPTTimeStamp The date and time stamp of the optical power transmitted
value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.38.1.9 |