thermalPowerOnDelay
BRCM-THERMAL-MGMT-MIB ·
.1.3.6.1.4.1.4413.2.2.2.1.11.1.4
Object
scalar
r/w
250 Milliseconds Unsigned32
This delay specifies the time between the Thermal Shutdown Controller detecting that the Power On Threshold has been reached and when it actually switches the unit back on. Its purpose is to allow power on the remainder of the board to stabilize. Serial communications are blocked during this delay, so it should be chosen carefully. The delay is specified in multiples of 50 milliseconds 2 to 50 ( 100ms - 2500ms ). The default is value is 5 yielding a delay of 250ms.
Context
- MIB
- BRCM-THERMAL-MGMT-MIB
- OID
.1.3.6.1.4.1.4413.2.2.2.1.11.1.4- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- 250 Milliseconds
- Parent
- thermalMgmtBase
- Siblings
- 6
Syntax
250 Milliseconds Unsigned32
Values & Constraints
Object Constraints
range: 2-50
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| thermalCurrentTemperature The Current Temperature of the Unit. | scalar | degrees C SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4413.2.2.2.1.11.1.1 |
| thermalPowerOffThreshold Specifies the Temperature Threshold at which the Thermal Shutdown Controller
will power down the unit. (40C to 120C). Note PowerOffThreshold must be
greater than PowerOnThreshold. | scalar | degrees C Integer32 | .1.3.6.1.4.1.4413.2.2.2.1.11.1.2 |
| thermalPowerOnThreshold Specifies the Temperature Threshold at which the Thermal Shutdown Controller
will switch power back on. (40C to 120C). Note PowerOnThreshold must be
less than PowerOffThreshold. | scalar | degrees C Integer32 | .1.3.6.1.4.1.4413.2.2.2.1.11.1.3 |
| thermalPowerOffDelay This delay is used to ensure the remainder of the board is completely powered
down prior to the Thermal Shutdown Circuit entering Over Temperature state.
Because some power supp… | scalar | Seconds Unsigned32 | .1.3.6.1.4.1.4413.2.2.2.1.11.1.5 |
| thermalNotificationDelay This delay is used to allow the main processor time to clean up (i.e. preserve
state information in non-volatile memory, and/or gracefully shut down a battery
subsystem) prior t… | scalar | Seconds Unsigned32 | .1.3.6.1.4.1.4413.2.2.2.1.11.1.6 |
| thermalMonitorInitialized This object returns true if the thermal monitor has been successfully initialized. | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.4413.2.2.2.1.11.1.7 |