thermalPowerOffThreshold

BRCM-THERMAL-MGMT-MIB · .1.3.6.1.4.1.4413.2.2.2.1.11.1.2

Object

scalar r/w degrees C Integer32
Specifies the Temperature Threshold at which the Thermal Shutdown Controller
will power down the unit. (40C to 120C). Note PowerOffThreshold must be
greater than PowerOnThreshold.

Context

MIB
BRCM-THERMAL-MGMT-MIB
OID
.1.3.6.1.4.1.4413.2.2.2.1.11.1.2
Type
scalar
Access
readwrite
Status
current
Units
degrees C
Parent
thermalMgmtBase
Siblings
6

Syntax

degrees C Integer32

Values & Constraints

Object Constraints
range: 40-120