cmDsCalZeroOffsets
BRCM-CM-FACTORY-MIB ·
.1.3.6.1.4.1.4413.2.99.1.1.2.2.3.6
Object
Setting this object to true(1) will result in all instances of cmDsCalOffset being set to a value of 0. Sets to false(2) will be accepted, but will not result in any action being taken. Reading this object always returns false(2).
Context
- MIB
- BRCM-CM-FACTORY-MIB
- OID
.1.3.6.1.4.1.4413.2.99.1.1.2.2.3.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- cmFactoryDownstreamCalibration
- Siblings
- 8
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cmDsCalFrequency The center of the downstream frequency to which the CM will
attempt to lock when cmDsCalLockNow is set to true. Note
that a read of this object does NOT necessarily indicate that… | scalar | hertz Integer32 | .1.3.6.1.4.1.4413.2.99.1.1.2.2.3.1 |
| cmDsCalModulation The modulation type that the CM will attempt to lock under
when cmDsCalLockNow is set to true. Note that a read of
this object does NOT necessarily indicate that the CM is
curre… | scalar | Enumeration | .1.3.6.1.4.1.4413.2.99.1.1.2.2.3.2 |
| cmDsCalLockNow When this object is set to true(1), the CM will attempt to lock to the
downstream channel at a frequency specified by cmDsCalFrequency,
and under the modulation type specified by… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.4413.2.99.1.1.2.2.3.3 |
| cmDsCalQamLocked Indicates whether the last set of cmDsCalLockNow to true resulted
in the CM acheiving QAM lock. Note that changing cmDsCalFrequency
or cmDsCalModulation will not affect the val… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.4413.2.99.1.1.2.2.3.4 |
| cmDsCalFecLocked Indicates whether the last set of cmDsCalLockNow to true resulted
in the CM acheiving FEC lock. Note that changing cmDsCalFrequency
or cmDsCalModulation will not affect the val… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.4413.2.99.1.1.2.2.3.5 |
| cmDsCalNumOffsets This object is read-only in normal factory mode, ie when
cableDataPrivateMibEnable is set to factory(1). In that context
it simply indicates the number of entries in the cmDsCal… | scalar | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4413.2.99.1.1.2.2.3.7 |
| cmDsCalOffsetTable A list offsets to be used when calculating downstream power for this
device. | table | - | .1.3.6.1.4.1.4413.2.99.1.1.2.2.3.8 |
| cmDsCalChannelNumber For bonded downstream systems, this object identifies which downstream
channel is to be calibrated. When the value of this object is changed,
the cmDsCalOffsetTable will be rebui… | scalar | Integer32 | .1.3.6.1.4.1.4413.2.99.1.1.2.2.3.9 |