voltageThresholdEntryWarningHighValue
BLADE-MIB ·
.1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.6
Object
column
mandatory
OctetString
Voltage threshold reading expressed in Volts(V).
If the voltage rises above this value, a warning
alert/event, if enabled, will be generated.
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space for a leading zero.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
Context
- MIB
- BLADE-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.6- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- voltageThresholdsEntry
- Table
- voltageThresholdsTable
- Siblings
- 6
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| voltageThresholdEntryIndex mandatory Index for voltage threshold entry. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.1 |
| voltageThresholdEntryWarningLowValue mandatory Voltage threshold reading expressed in Volts(V).
If the voltage drops below this value, a warning
alert/event, if enabled, will be generated.
An octet string expressed as 'sdd.dd … | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.10 |
| voltageThresholdEntryWarningResetLowValue mandatory Voltage threshold reading expressed in Volts(V).
If the voltage drops below this value and
if a warning alert/event had previously been
created, then the alert/event will be reset… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.11 |
| voltageThresholdEntryName mandatory Voltage threshold entry null terminated string that
contains the power supply's name, for example '+5V'. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.2 |
| voltageThresholdEntryCurrentValue mandatory Voltage reading expressed in Volts(V).
An octet string expressed as 'sdd.dd Volts' where:
s is the sign ('-' for negative or '+' for positive)
d is a decimal digit or blank space … | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.3 |
| voltageThresholdEntryWarningResetHighValue mandatory Voltage threshold reading expressed in Volts(V).
If the voltage rises above this value and
if a warning alert/event had previously been
created, then the alert/event will be reset… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.7 |