telcoAlarmSet

BLADE-MIB · .1.3.6.1.4.1.2.3.51.2.5.1.1

Object

scalar mandatory r/w OctetString
Create a software alarm. An input octet string consists of the
alarm severity level and the alarm description (40 bytes max).
The following severity levels are valid :
     CRT Critical
     MJR Major
     MNR Minor
          
NOTE 1: The level (e.g. MJR) and alarm description string must
be separated by a blank, otherwise, a badValue error will be returned. 
          
NOTE 2: Value returned for the GET command is meaningless for
this MIB object.
          
NOTE 3: This MIB object is for BladeCenter T only.

Context

MIB
BLADE-MIB
OID
.1.3.6.1.4.1.2.3.51.2.5.1.1
Type
scalar
Access
readwrite
Status
mandatory
Parent
telcoAlarmReq
Siblings
2

Syntax

OctetString

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects