switchZoneCfgActivation
BLADE-MIB ·
.1.3.6.1.4.1.2.3.51.2.22.6.2.1.3
Object
scalar
mandatory
r/w
Integer32
This object provides a quick means of activating a valid zone
configuration on all active SAS switches. The zone configuration
to be activated is specified as the value of the SET and can be
obtained from the switchZoneCfgNumber object.
The zone configuration number is also referred to as the zone
configuration store.
Before activating a new zone configuration, a user must consider
the following:
1) Changing the zone configuration may cause disruption in the storage
access of blades connected to this SAS Module. It is highly recommended
that you first ensure that the blades have completed all storage accesses.
You may want to shutdown the blade OS prior to changing your zone configuration.
2) When selecting a zone configuration, ensure that it is appropriate
for the number of SAS switches installed in your chassis. This can
be determined from the switchZoneCfgDescription text.
3) When selecting a zone configuration, ensure that it exists first on
all SAS switches. This can be determined by querying the
storageSwitchZoneCfgTable. In addition, for user-defined zone
configurations, even if the number is the same, ensure that the
actual zone configurations are identical or compatible. You will need
to use an application, such as the Switch Configuration Manager (SCM)
to verify this.
4) All SAS switches must be in operational state prior to activating a
new zone configuration. This can be determined by querying the
activeZoneCfgNumberBySwitch object and ensuring that none of the
2xx codes are returned.
NOTE: Value returned for the GET command is meaningless
for this MIB object.
If any of the switches are not activated, an error response
will be returned.
Context
- MIB
- BLADE-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.22.6.2.1.3- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- storageSwitchConfiguration
- Siblings
- 2
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| storageSwitchZoneCfgTable mandatory Table of all the zone configurations stored on switch
modules. For consistent results, view as a table and
not as individual entries.
Before activating a new zone confi… | table | - | .1.3.6.1.4.1.2.3.51.2.22.6.2.1.1 |
| storageSwitchActiveZoneCfgTable mandatory Table showing the zone configuration that is currently
active on a given switch module. For consistent results,
view as a table and not as individual entries. | table | - | .1.3.6.1.4.1.2.3.51.2.22.6.2.1.2 |