remoteAlertsCrit
BLADE-MIB ·
.1.3.6.1.4.1.2.3.51.2.4.2.1
Object
node
No description available.
Context
- MIB
- BLADE-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.4.2.1- Type
- node
- Parent
- remoteAlerts
- Siblings
- 3
- Children
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| remoteAlertsNonCrit | node | - | .1.3.6.1.4.1.2.3.51.2.4.2.2 |
| remoteAlertsSystem | node | - | .1.3.6.1.4.1.2.3.51.2.4.2.3 |
| alertMode mandatory Selects which alert categories will be displayed on the
web interface, which alert category objects are accessible
through SNMP, and which SNMP trap type an alert is associated wi… | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.4 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| critTemp obsolete Generate an alert if any of the monitored temperature sensors
in the system exceed their critical threshold.
NOTE: If a critical Temperature condition is detected,
the … | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.1 |
| critBlade mandatory Generate an alert for any critical error condition on a blade.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all … | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.10 |
| critIO mandatory Generate an alert for any critical error condition on I/O module.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for a… | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.11 |
| critStorage mandatory Generate an alert for any critical error condition on a Storage module.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used… | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.12 |
| critChassis mandatory Generate an alert for any critical error condition on chassis.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all … | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.13 |
| critFan mandatory Generate an alert for any critical error condition on cooling devices.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used … | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.14 |
| critVolt obsolete Generate a alert if any of the monitored power supply sensors
in the system fall outside their specified critical
operational range.
NOTE: If a critical voltage conditi… | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.2 |
| critMultiBlower obsolete Generate an alert if multiple blowers used for cooling the system fail.
NOTE: Blowers are also referred to as Chassis Cooling Devices.
NOTE: The legacy(0) mo… | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.4 |
| critPower mandatory Generate an alert if any of the system power supplies fail.
NOTE: This object is valid when the alertMode object is
set enhanced(1) and should be used for all ale… | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.5 |
| critHardDrive obsolete Generate an alert if any of hard disk drives fail.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several releases. They ar… | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.6 |
| critVRM obsolete Generate an alert if any of VRM (voltage regulator modules) fail.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several re… | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.7 |
| critMultipleSwitchModule obsolete Generate an alert if all switch modules fail or are removed.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several release… | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.8 |
| critInvalidConfig obsolete Generate an alert if the hardware configuration is incompatible.
NOTE: The legacy(0) mode alerts should no longer be used
and have been deprecated for several rel… | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.2.1.9 |