pd2BladePrimarySlot
BLADE-MIB ·
.1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.3
Object
column
mandatory
Enumeration
Power Domain 2 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is double wide and is installed in slot 3 and 4. 3 is primary slot while 4 is not.
Context
- MIB
- BLADE-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.3- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- powerDomain2Entry
- Table
- powerDomain2Table
- Siblings
- 12
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pd2Index mandatory Power Domain 2 Table Index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.1 |
| pd2ModuleCPUDutyCycles mandatory Power Domain 2 Table Module CPUs Duty Cycles applies to blade
servers only. It displays the duty cycle for each CPU on the blade
as a percentage. Note that some blades do not re… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.10 |
| pd2ModuleThrottle mandatory Power Domain 2 Table Module Throttle indicates whether the
server blade may be allowed to throttle or not.
When a 1200W or 1400W power module is installed in the domain
the power … | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.11 |
| pd2ModulePowerCapabilities mandatory Power Domain 2 Table Module Power Capabilities.
staticPowerManagement: the module with the static worst
case power values.
fixedPowermanagement: the module with… | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.12 |
| pd2ModuleMeasuredOrStatic mandatory Power Domain 2 Table Module Measured Or Static. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.13 |
| pd2BayNumber mandatory Power Domain 2 Table Bay Number.
The following Bay Number IDs are used in the BladeCenter:
serverBladeBay7(1),
serverBladeBay8(2),
serverBladeBay9(3),
serverBladeBay10(4),
se… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.2 |
| pd2ModuleStatus mandatory Power Domain 2 Table Module throttle status. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.4 |
| pd2ModuleName mandatory Power Domain 2 Table Module Name. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.5 |
| pd2ModuleState mandatory Power Domain 2 Table Power State. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.6 |
| pd2ModuleAllocatedPowerCurrent mandatory Power Domain 2 Table Allocated Power Current indicates the current power
allocation for the module. When a 1200W or 1400W power module is
installed in the domain the power managem… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.7 |
| pd2ModuleAllocatedPowerMax mandatory Power Domain 2 Table Allocated Power Max indicates the maximum power
allocation for the module in Watts. It is indicative of the maximum
amount of power the module will consume i… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.8 |
| pd2ModuleAllocatedPowerMin mandatory Power Domain 2 Table Allocated Power Min indicates the minumum power
allocation for the module in Watts. It is indicative of the minumum
power consumption of the component in the… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.9 |