potsIfFxoDataLinkModeOnHook

BINTEC-POTS-MIB · .0.14.1.2.1.33

Object

column r/w Bits
Allowed on-hook data transmission modes:
dt-as:          data transmission prior to ringing with DT-AS
dt-as-pol-rev:  data transmission prior to ringing with DT-AS 
                and polarity reversal
rp-as:          data transmission prior to ringing with RP-AS
during-ringing: data transmission during ringing (after first ring)
dtmf:           data transmission using DTMF
              
With no bit activated on-hook data transmission is disabled.

Context

MIB
BINTEC-POTS-MIB
OID
.0.14.1.2.1.33
Type
column
Access
readwrite
Status
current
Parent
potsIfFxoEntry
Table
potsIfFxoTable
Siblings
41

Syntax

Bits

Values & Constraints

Enumerated Values
0dt-as
1dt-as-pol-rev
2rp-as
3during-ringing
4dtmf

Related Objects