sysX8ConfigFanControl
BIANCA-X8000-MIBSYS-MIB ·
.1.3.6.1.4.1.272.4.17.3.1.9
Object
scalar
mandatory
r/w
Enumeration
This variable defines automatic fan control. In mode 'auto' the fans are automatically adjusted depending on the current temperature. In mode 'high' all fans remain at maximum speed.
Context
- MIB
- BIANCA-X8000-MIBSYS-MIB
- OID
.1.3.6.1.4.1.272.4.17.3.1.9- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- sysX8Config
- Siblings
- 13
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | auto |
2 | high |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sysX8ConfigPowerSupply1State mandatory This variable shows the state of the power supply. | scalar | Enumeration | .1.3.6.1.4.1.272.4.17.3.1.1 |
| sysX8ConfigFanVersion mandatory This variable shows the firmware version of
the fan unit. | scalar | - | .1.3.6.1.4.1.272.4.17.3.1.10 |
| sysX8ConfigFan1 mandatory This variable shows the current turning speed. | scalar | Integer32 | .1.3.6.1.4.1.272.4.17.3.1.11 |
| sysX8ConfigFan2 mandatory This variable shows the current turning speed. | scalar | Integer32 | .1.3.6.1.4.1.272.4.17.3.1.12 |
| sysX8ConfigFan3 mandatory This variable shows the current turning speed. | scalar | Integer32 | .1.3.6.1.4.1.272.4.17.3.1.13 |
| sysX8ConfigFan4 mandatory This variable shows the current turning speed. | scalar | Integer32 | .1.3.6.1.4.1.272.4.17.3.1.14 |
| sysX8ConfigPowerSupply1Temp mandatory This variable shows the actual power supply temperature
in the unit Celsius. | scalar | Integer32 | .1.3.6.1.4.1.272.4.17.3.1.2 |
| sysX8ConfigPowerSupply1TempAlarmThreshold mandatory Power supply 1 temperature threshold. | scalar | Integer32 | .1.3.6.1.4.1.272.4.17.3.1.3 |
| sysX8ConfigPowerSupply1TempAlarmTrap mandatory If the power supply temperature raises above the threshold,
a alarm trap is generated every 60 seconds. | scalar | Enumeration | .1.3.6.1.4.1.272.4.17.3.1.4 |
| sysX8ConfigPowerSupply2State mandatory This variable show the the state of the power supply. | scalar | Enumeration | .1.3.6.1.4.1.272.4.17.3.1.5 |
| sysX8ConfigPowerSupply2Temp mandatory This variable shows the actual power supply temperature
in the unit Celsius. | scalar | Integer32 | .1.3.6.1.4.1.272.4.17.3.1.6 |
| sysX8ConfigPowerSupply2TempAlarmThreshold mandatory Power supply 2 temperature threshold. | scalar | Integer32 | .1.3.6.1.4.1.272.4.17.3.1.7 |
| sysX8ConfigPowerSupply2TempAlarmTrap mandatory If the power supply temperature raises above the threshold,
a alarm trap is generated every 60 seconds. | scalar | Enumeration | .1.3.6.1.4.1.272.4.17.3.1.8 |