wlcACBintecConfigTimer
BIANCA-BRICK-WIRELESS-CONTROLLER-MIB ·
.0.61.1.1.10
Object
scalar
r/w
s Integer32
This timer defines how long a WTP waits for the next bintec config message before it supposes the AC to be down. Default is 10.
Context
- MIB
- BIANCA-BRICK-WIRELESS-CONTROLLER-MIB
- OID
.0.61.1.1.10- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- s
- Parent
- wlcAC
- Siblings
- 12
Syntax
s Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wlcACAdminStatus Global AC switch, that defines the role of this device. | scalar | Enumeration | .0.61.1.1.1 |
| wlcACLostACLifetime This timer defines in seconds how long a WTP still hold its configuration
after he has lost the connection to its AC.
The value -1 means endless. Default is 0, which means the WTP… | scalar | s Integer32 | .0.61.1.1.11 |
| wlcACLedMode Choose one of the following LED-Modes for all manages WTPs:
normal : LEDs work normal,
minimal : only Status-LED blinks once in a second,
off := LEDs are off. | scalar | Enumeration | .0.61.1.1.12 |
| wlcACScanResultsMaxAge If a scan result wasn't seen for so many seconds,
it will be removed from wlcScanResultsTable. | scalar | seconds Integer32 | .0.61.1.1.13 |
| wlcACOperStatus This attribute shows the current
AC operation state. | scalar | Enumeration | .0.61.1.1.2 |
| wlcACMaxNoWTP Max number of WTPs that the AC can handle. | scalar | Integer32 | .0.61.1.1.3 |
| wlcACIfIndex Interface index where the AC is listening. | scalar | Integer32 | .0.61.1.1.4 |
| wlcACDebugLevel WLAN Controller degugging verbosity level. With a higher value
more debugging information will be created.
Default is normal(2). | scalar | Enumeration | .0.61.1.1.5 |
| wlcACAction Setting this variable to channel_selecting(2) a successive
channel reallocation is issued.
Setting this variable to start_scanning(3) a successive
neighborhood scan on all active … | scalar | Enumeration | .0.61.1.1.6 |
| wlcACInitType This variable indicates whether initialisation of WTPs is
done simultaneous(1) (more than one is initialised at the
same time) or successive(2) (one after the other).
Default is s… | scalar | Enumeration | .0.61.1.1.7 |
| wlcACNoSimultaneousInit This attribute defines how many WTPs can be initialised
simultaneously in wlcACInitType_simultaneous.
A value of 0 defines that all WTPs can be initialised at the same time.
Defau… | scalar | Integer32 | .0.61.1.1.8 |
| wlcACStatisticsTimer This timer defines the interval statistics are sent from WTP to AC.
Default is 30. | scalar | s Integer32 | .0.61.1.1.9 |