wlcACAction
BIANCA-BRICK-WIRELESS-CONTROLLER-MIB ·
.0.61.1.1.6
Object
scalar
r/w
Enumeration
Setting this variable to channel_selecting(2) a successive channel reallocation is issued. Setting this variable to start_scanning(3) a successive neighborhood scan on all active radios is initialised. After all radios are set to client mode it is switched to scanning(4) by system. On all operations switching back to idle(1) indicates that the operation has finished. Default is idle(1).
Context
- MIB
- BIANCA-BRICK-WIRELESS-CONTROLLER-MIB
- OID
.0.61.1.1.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- wlcAC
- Siblings
- 12
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | idle |
2 | channel-selecting |
3 | start-scanning |
4 | scanning |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wlcACAdminStatus Global AC switch, that defines the role of this device. | scalar | Enumeration | .0.61.1.1.1 |
| wlcACBintecConfigTimer This timer defines how long a WTP waits for the next bintec config
message before it supposes the AC to be down.
Default is 10. | scalar | s Integer32 | .0.61.1.1.10 |
| wlcACLostACLifetime This timer defines in seconds how long a WTP still hold its configuration
after he has lost the connection to its AC.
The value -1 means endless. Default is 0, which means the WTP… | scalar | s Integer32 | .0.61.1.1.11 |
| wlcACLedMode Choose one of the following LED-Modes for all manages WTPs:
normal : LEDs work normal,
minimal : only Status-LED blinks once in a second,
off := LEDs are off. | scalar | Enumeration | .0.61.1.1.12 |
| wlcACScanResultsMaxAge If a scan result wasn't seen for so many seconds,
it will be removed from wlcScanResultsTable. | scalar | seconds Integer32 | .0.61.1.1.13 |
| wlcACOperStatus This attribute shows the current
AC operation state. | scalar | Enumeration | .0.61.1.1.2 |
| wlcACMaxNoWTP Max number of WTPs that the AC can handle. | scalar | Integer32 | .0.61.1.1.3 |
| wlcACIfIndex Interface index where the AC is listening. | scalar | Integer32 | .0.61.1.1.4 |
| wlcACDebugLevel WLAN Controller degugging verbosity level. With a higher value
more debugging information will be created.
Default is normal(2). | scalar | Enumeration | .0.61.1.1.5 |
| wlcACInitType This variable indicates whether initialisation of WTPs is
done simultaneous(1) (more than one is initialised at the
same time) or successive(2) (one after the other).
Default is s… | scalar | Enumeration | .0.61.1.1.7 |
| wlcACNoSimultaneousInit This attribute defines how many WTPs can be initialised
simultaneously in wlcACInitType_simultaneous.
A value of 0 defines that all WTPs can be initialised at the same time.
Defau… | scalar | Integer32 | .0.61.1.1.8 |
| wlcACStatisticsTimer This timer defines the interval statistics are sent from WTP to AC.
Default is 30. | scalar | s Integer32 | .0.61.1.1.9 |