bfdSessReqMinRxInterval

BFD-STD-MIB-R · .1.3.6.1.4.1.164.20.15.1.2.1.25

Object

column r/w BFD-TC-STD-MIB-RBfdIntervalTC
This object specifies the minimum interval, in
microseconds, between received  BFD Control packets the
local system is capable of supporting. The value of
zero(0) can be specified when the transmitting system
does not want the remote system to send any periodic BFD
control packets.

Context

MIB
BFD-STD-MIB-R
OID
.1.3.6.1.4.1.164.20.15.1.2.1.25
Type
column
Access
readwrite
Status
current
Parent
bfdSessEntry
Table
bfdSessTable
Siblings
35

Syntax

BFD-TC-STD-MIB-RBfdIntervalTC
Source
BFD-TC-STD-MIB-RBfdIntervalTC
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Related Objects

Sibling Objects