upsWellKnownAlarms
BESTPOWER-MIB ·
.1.3.6.1.4.1.2947.1.8.4
Object
node
No description available.
Context
- MIB
- BESTPOWER-MIB
- OID
.1.3.6.1.4.1.2947.1.8.4- Type
- node
- Parent
- upsAlarm
- Siblings
- 3
- Children
- 36
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAlarmsPresent mandatory The present number of active alarm conditions. | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.2947.1.8.1 |
| upsLastKnownAlarm mandatory A unique identifier for an alarm condition. This
value must remain constant. Value 'noAlarm(37)'
will be returned if no Alarm has occured till the
point of GET operation. | scalar | Enumeration | .1.3.6.1.4.1.2947.1.8.2 |
| upsAlarmTable mandatory A list of alarm table entries. The table contains
zero, one, or many rows at any moment, depending upon
the number of alarm conditions in effect. The table
is initially empty at… | table | - | .1.3.6.1.4.1.2947.1.8.3 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAlarmOnBattery mandatory The UPS is drawing power from the batteries. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.1 |
| upsAlarmOutputOverload mandatory The output load exceeds the UPS output capacity. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.10 |
| upsAlarmLowAcOut mandatory The output load has exceeded the UPS output capacity, and the UPS has shut down. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.11 |
| upsAlarmCircuitBreakerWarning mandatory To much load equipment has been connected to the UPS and has has caused excess
current draw from the output. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.12 |
| upsAlarmCircuitBreakerShdn mandatory The UPS has shut down due to an extended excess of current draw
from the output. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.13 |
| upsAlarmBypassOn mandatory The Bypass is presently engaged on the UPS. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.14 |
| upsAlarmAutoBypass mandatory The UPS has gone into the Auto Bypass mode to redirect power around
the UPS circuitry. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.15 |
| upsAlarmSiteWiringFault mandatory The UPS has found a problem in your wall outlet. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.16 |
| upsAlarmCheckFan mandatory The fan on the UPS has stopped | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.17 |
| upsAlarmHighAmbTemp mandatory The internal temperature inside the UPS is too hot. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.18 |
| upsAlarmHighHSTemp mandatory The Inverter heatsink assembly inside the UPS is to hot . | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.19 |
| upsAlarmLowRuntime mandatory The remaining battery runtime is less than or equal
to the upsConfigLowRuntimeSetpoint. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.2 |
| upsAlarmHighXFMRTemp mandatory The temperature of the main transformer inside the UPS is too hot . | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.20 |
| upsAlarmHighPFMTemp mandatory The temperature of the PFM module inside the UPS is too hot . | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.21 |
| upsAlarmProbeMissing mandatory One or all of the sense probes has been disconnected on the UPS. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.22 |
| upsAlarmCheckPowerSupply mandatory The internal DC supply voltages are attenuated or missing. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.23 |
| upsAlarmTapRegulator mandatory The UPS detected a possible failure in the tap changer (open or
welded relay, etc.) | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.24 |
| upsAlarmRelayFailure mandatory There is a hardware problem inside the UPS. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.25 |
| upsAlarmCheckFuse mandatory The failure of one or more fuses has been detected. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.26 |
| upsAlarmCheckMOV mandatory One or more MOVs have failed due to a voltage surge. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.27 |
| upsAlarmMemoryError mandatory The UPS has lost the programmed settings in the memory of the logic
board. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.28 |
| upsAlarmCallService mandatory A hardware malfunction has occurred inside the UPS. Please consult a
factory authorized service representative for assistance. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.29 |
| upsAlarmNearLowBattery mandatory The battery voltage on the UPS has reached a value where the inverter will
not be able to function very much longer. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.3 |
| upsAlarmupsFailed mandatory A general fault in the UPS has been detected. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.30 |
| upsAlarmUserTest mandatory A user test of the alarm beeper is in progress. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.31 |
| upsAlarmTestInProgress mandatory A test is in progress. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.32 |
| upsAlarmDiagnosticTestFailed mandatory The result of the last diagnostic test indicates a failure. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.33 |
| upsAlarmEPO mandatory The Emergency Power OFF feature has been activiated at the RS-232
port on the UPS. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.34 |
| upsAlarmUpsOff mandatory The output of the UPS is in the off state. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.35 |
| upsAlarmCommunicationsLost mandatory A problem has been encountered in the
communications between the agent and the UPS. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.36 |
| upsAlarmLowBattery mandatory The battery voltage on the UPS has reached a value where the inverter
has stopped providing output power to the connected load equipment.
The UPS has shutdown to protect the batte… | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.4 |
| upsAlarmHighBattery mandatory The battery charger voltage on the UPS has reached a value that
is too high for safe battery maintenance. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.5 |
| upsAlarmCheckBattery mandatory The periodic battery test has failed. A manual test of the batteries
needs to be performed to determine which battery\batteries need
replaced. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.6 |
| upsAlarmReplaceBattery mandatory One or more batteries have been determined to require
replacement. Compatibility: Fortress II | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.7 |
| upsAlarmCheckInverter mandatory The inverter has failed the automatic system test. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.8 |
| upsAlarmBatteriesDisconnected mandatory The UPS has detected that the DC voltage needed to start up is too
low or missing. | scalar | Integer32 | .1.3.6.1.4.1.2947.1.8.4.9 |