bdQTime
BD-MIB ·
.1.3.6.1.4.1.1588.2.1.1.51.1.4
Object
scalar
seconds Integer32
The minimum number of seconds between consecutive alerts. The value assigned to this parameter applies to both latency and congestion monitoring. In this duration, there will not be any traps sent.
Syntax
seconds Integer32
Values & Constraints
Object Constraints
range: 1-1000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| bdStatus This object gives the status of bottleneck detection feature
if enabled in the switch. The value of this OID if true(1) or false(2). | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.1588.2.1.1.51.1.1 |
| bdLThreshold This object is the severity threshold for latency bottleneck.
This threshold indicates the percentage of one-second intervals
affected by latency conditions within a specified ti… | scalar | OctetString | .1.3.6.1.4.1.1588.2.1.1.51.1.2 |
| bdCThreshold This object is the severity threshold for congestion bottleneck.
This threshold indicates the percentage of one-second intervals
affected by congestion conditions within a speci… | scalar | OctetString | .1.3.6.1.4.1.1588.2.1.1.51.1.3 |
| bdWinAvgTime The time window in seconds over which the percentage of seconds
affected by bottleneck conditions is computed and compared
with the threshold. | scalar | seconds Integer32 | .1.3.6.1.4.1.1588.2.1.1.51.1.5 |
| bdThreshold This is the severity threshold for latency or congestion
bottleneck. This is accessible only for traps. This object is
one of the variable binding in bdTrap and bdClearTrap. | scalar | OctetString | .1.3.6.1.4.1.1588.2.1.1.51.1.6 |
| nBdType This is the type of bottleneck.This is accessible only for
traps. This object is one of the variable binding in bdTrap and
bdClearTrap. This can have a value of congestion(1) or… | scalar | BdType | .1.3.6.1.4.1.1588.2.1.1.51.1.7 |