shelfNum
BASIS-SHELF-MIB ·
.1.3.6.1.4.1.351.110.1.1.1.1.1
Object
column
mandatory
Integer32
A unique value for each shelf. Its value ranges between 1 and the maxvalue of shelfNumber.
Context
- MIB
- BASIS-SHELF-MIB
- OID
.1.3.6.1.4.1.351.110.1.1.1.1.1- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- shelfEntry
- Table
- shelfTable
- Siblings
- 5
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-4
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| shelfSlotNum mandatory Slot number of a card.
BASIS can have maximum 16 slots in one shelf.
17 is used to reset the whole shelf.
Some MGX Series can have maximum 32 slots in one shelf.
33 is used to re… | column | Integer32 | .1.3.6.1.4.1.351.110.1.1.1.1.2 |
| shelfBkplnSerialNumDeprecated mandatory This entry has been deprecated. It is available as the 9th
entry in basisShelf. It is included here to prevent a hole
in the shelfEntry table. | column | Integer32 | .1.3.6.1.4.1.351.110.1.1.1.1.3 |
| shelfFunctionModuleState mandatory This object holds the status of a card in a particular shelf-slot.
The hold state is applicable only to MGX8800 Platform.
The Slave PXM assumes the hold state during PXM Upgrades.… | column | Enumeration | .1.3.6.1.4.1.351.110.1.1.1.1.4 |
| shelfFunctionModuleType mandatory This object holds the type of a card in
a particular shelf-slot. | column | Enumeration | .1.3.6.1.4.1.351.110.1.1.1.1.5 |
| shelfFunctionModuleHoldReset mandatory This object holds the card in
a particular shelf-slot, in reset,
If the object is set to holdInReset.
If the object is set to doNotHold, then
it only reset the card in the spec… | column | Enumeration | .1.3.6.1.4.1.351.110.1.1.1.1.6 |