fsMIRstFlushIndicationThreshold

Aricent-MIRSTP-MIB · .1.3.6.1.4.1.2076.119.1.3.1.22

Object

column r/w Integer32
This object specifies the number of flush indications to go before
timer method triggers. (i.e.) the number of flush indications
 to trigger the FlushInterval Timer. 
              	 
 This value can be configurable only when fsMIRstFlushInterval
 is other than default value. 
              	 
 When the value is retained as default value and flush interval 
 is being configured other than default value(0), then 
 global flushing will happen. 
              	 
 When this value is non-default and the flush interval is being 
 configured other than default value(0), then the port
 based flushing will happen until the actual flush indication 
 reaches the threshold. Once the threshold is reached, timer 
 will be started and during timer expiry global flushing will 
 happen.

Context

MIB
Aricent-MIRSTP-MIB
OID
.1.3.6.1.4.1.2076.119.1.3.1.22
Type
column
Access
readwrite
Status
current
Parent
fsMIDot1wFutureRstEntry
Table
fsMIDot1wFutureRstTable
Siblings
26

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-65535

Related Objects