hr40165
ASCO-QEM-72EE2 ·
.1.3.6.1.4.1.7777.1.7.165
Object
scalar
OctetString
MODBUS HR 40165-174: BIC Location.
Context
- MIB
- ASCO-QEM-72EE2
- OID
.1.3.6.1.4.1.7777.1.7.165- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- bic
- Siblings
- 36
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-11
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hr40109 MODBUS HR 40109-112: BIC Tag Name. | scalar | OctetString | .1.3.6.1.4.1.7777.1.7.109 |
| hr40119 MODBUS HR 40119: Normal Voltage Dropout. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.119 |
| hr40120 MODBUS HR 40120: Normal Voltage PickUp. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.120 |
| hr40121 MODBUS HR 40121: Normal Over Voltage Trip. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.121 |
| hr40122 MODBUS HR 40122: Normal Frequency DropOut. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.122 |
| hr40123 MODBUS HR 40123: Normal Frequency PickUp. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.123 |
| hr40124 MODBUS HR 40124: Normal Over Frequency Trip. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.124 |
| hr40126 MODBUS HR 40126: Emergency Voltage Dropout. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.126 |
| hr40127 MODBUS HR 40127: Emergency Voltage PickUp. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.127 |
| hr40128 MODBUS HR 40128: Emergency Over Voltage Trip. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.128 |
| hr40129 MODBUS HR 40129: Emergency Frequency DropOut. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.129 |
| hr40013 MODBUS HR 40013: Normal Frequency. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.13 |
| hr40130 MODBUS HR 40130: Emergency Frequency PickUp. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.130 |
| hr40131 MODBUS HR 40131: Emergency Over Frequency Trip. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.131 |
| hr40014 MODBUS HR 40014: Emergency Frequency. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.14 |
| hr40015 MODBUS HR 40015: ATS, BTS & Load Status.
40015:00 ATS on Norm
40015:01 ATS on Emer
40015:02 Bypassed to Norm
40015:03 Bypassed to Emer
40015:04 Norm Avail
40015:05 Emer… | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.15 |
| hr40019 MODBUS HR 40019: Normal Voltage CA. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.19 |
| hr40023 MODBUS HR 40023: Emergency Voltage CA. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.23 |
| hr40025 MODBUS HR 40025: Nominal Voltage. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.25 |
| hr40254 MODBUS HR 40254: Bypass LockOut Active. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.254 |
| hr40256 MODBUS HR 40256: BIC Alarm Status.
40256:00 Alarm
40256:01 DiagnosticMode
40256:02 Isolation position sensor error
40256:03 ATS position switch error
40256:04 BTS trans… | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.256 |
| hr40026 MODBUS HR 40026: Nominal Frequency. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.26 |
| hr40028 MODBUS HR 40028-32: Control Panel Software Version. | scalar | OctetString | .1.3.6.1.4.1.7777.1.7.28 |
| hr40034 MODBUS HR 40034-38: Control Panel Software Version. | scalar | OctetString | .1.3.6.1.4.1.7777.1.7.34 |
| hr40039 MODBUS HR 40039: CPLD & BIC Hardware Version. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.39 |
| hr40043 MODBUS HR 40043: ATS Control Inihibit. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.43 |
| hr40055 MODBUS HR 40055: Total No. of Logged Events. | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.55 |
| hr40081 MODBUS HR 40081: CAN Communication Configurations.
40081:00-06 CAN Port Address
40081:07 Can Port Enable
40081:08-10 CAN Port Baud Rate | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.81 |
| hr40087 MODBUS HR 40087: BIC Output Status.
40087:00 notInAuto/ AA12
40087:01 isoRackOnConn/ AA 6
40087:02 isoRackOnTest/ AA 8
40087:03 isoRackOnIsolated/ AA 7
40087:04 okToCon… | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.87 |
| hr40088 MODBUS HR 40088: BIC Sensor Input.
40088:00 Sensor Input Connect/Conn-Test
40088:01 Sensor Input Connected
40088:02 Sensor Input Conn-Test/Test/Test-Isolated
40088:03 S… | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.88 |
| hr40089 MODBUS HR 40089: BIC & ATS Switch Position.
40089:00 BTS Position Inputs BTS Norm On
40089:01 BTS Position Inputs BTS Norm Off
40089:02 BTS Position Inputs BTS Emer On
… | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.89 |
| hr40090 MODBUS HR 40090: CPLD DIP Switch Status.
40090:00 CPLD Dipswitch Bit 0
40090:01 CPLD Dipswitch Bit 1
40090:02 CPLD Dipswitch Bit 2
40090:03 CPLD Dipswitch Bit 3
400… | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.90 |
| hr40091 MODBUS HR 40091: BTS Coil Status.
40091:00 Coil Pwr Mon 1
40091:01 Coil Power Enable
40091:02 Coil Power Select | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.91 |
| hr40092 MODBUS HR 40091: BTS Handle Position Status.
40092:00 BTS Handle Position Off
40092:01 BTS Handle Position Norm
40092:02 BTS Handle Position Emer | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.92 |
| hr40093 MODBUS HR 40093-98: Serial Number. | scalar | OctetString | .1.3.6.1.4.1.7777.1.7.93 |
| hr40099 MODBUS HR 40099: BIC PuchButton Status.
40099:00 BP to Norm
40099:01 BP to Emer
40099:02 Unbypass
40099:03 Lamp Test | scalar | Integer32 | .1.3.6.1.4.1.7777.1.7.99 |