eqptPortMappingGlobalChangeCounter
ASAM-EQUIP-MIB ·
.1.3.6.1.4.1.637.61.1.23.14
Object
This counter represents the number of global PortMapping configuration changes. It is a wraparound counter between 0 and MAX. SUPPORT: YES INSRVMOD: NA RANGE: 0-MAX PERSIST: NO DEFVALUE: 0 UNITS: -
Context
- MIB
- ASAM-EQUIP-MIB
- OID
.1.3.6.1.4.1.637.61.1.23.14- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- asamEquipmentMIB
- Siblings
- 17
Syntax
RFC1155-SMICounter
- Source
- RFC1155-SMICounter
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eqptAsam | node | - | .1.3.6.1.4.1.637.61.1.23.1 |
| eqptBoardThermalSensorTable mandatory A table representing the actual value and thresholds of Thermal Sensor(s) on boards.
One entry corresponds to each sensor on board.
The entries are presented only when the board i… | table | - | .1.3.6.1.4.1.637.61.1.23.10 |
| eqptPortMappingTable mandatory Equipment PortMapping table, showing the mapping between logical ports
and physical ports (faceplate numbering).
This table contains one row per logical port on the xHU… | table | - | .1.3.6.1.4.1.637.61.1.23.13 |
| eqptPortProtectionTable mandatory This table holds the port protection groups | table | - | .1.3.6.1.4.1.637.61.1.23.15 |
| eqptPortProtectionLookupTable mandatory This table holds the lookup port protection groups | table | - | .1.3.6.1.4.1.637.61.1.23.16 |
| eqptBoardPlannedResourceTable mandatory A table representing the actual values of configured hardware
resources on boards.
This table only displays entries for resources on the boards
that support this view. These are b… | table | - | .1.3.6.1.4.1.637.61.1.23.17 |
| eqptPowerTable mandatory Equipment power table, representing the power management objects per
system, rack or shelf.
This table contains one row for the system, rack or shelf that is
subject to power mana… | table | - | .1.3.6.1.4.1.637.61.1.23.18 |
| eqptPowerSupplyTable mandatory Equipment power table, representing the power suplly management objects
This table contains one row per power supply supported on the system.
In other cases no entry is instantiat… | table | - | .1.3.6.1.4.1.637.61.1.23.19 |
| eqptHolderTable mandatory Equipment holder table, representing the system, the racks and
the shelves.
This table contains one row for the system, one row per rack,
and one row per shelf.
… | table | - | .1.3.6.1.4.1.637.61.1.23.2 |
| eqptPowerSupplyRftc | node | - | .1.3.6.1.4.1.637.61.1.23.20 |
| eqptBoardTable mandatory A table representing the slots of all planned shelves. Each slot
can hold a board of one of the following types: NT, EXT, LSM,
ACU, CTRL, applique.
This table has a row… | table | - | .1.3.6.1.4.1.637.61.1.23.3 |
| eqptShelfSummaryTable mandatory Shelf summary table, summarizing slot or board related status
changes within each shelf.
This table has one row per planned shelf.
ALCATEL NOTE:
SUPPORT: … | table | - | .1.3.6.1.4.1.637.61.1.23.4 |
| eqptProt | node | - | .1.3.6.1.4.1.637.61.1.23.5 |
| eqptProfile | node | - | .1.3.6.1.4.1.637.61.1.23.6 |
| eqptTestChainTable mandatory A table contains the test chain configuration indicating
which shelf is connected to the TAP_UP or whether an external
test head is connected to the TAP_UP. This table has one row… | table | - | .1.3.6.1.4.1.637.61.1.23.7 |
| eqptCustAlarmProfile | node | - | .1.3.6.1.4.1.637.61.1.23.8 |
| eqptMtaTest | node | - | .1.3.6.1.4.1.637.61.1.23.9 |