asamAlarmSnapshotSeverityLevel

ASAM-ALARM-MIB · .1.3.6.1.4.1.637.61.1.3.19

Object

scalar mandatory r/w AsamAlarmSeverityType
This object indicates the lowest severity level of alarms that
should be visible in the snapshot table. When the snapshot table
status is in the notInUse state, the severity cannot be read or set.
When the snapshot table status is in the InUse state, the severity
level can only be set once to prevent confusion as to the lowest
severity in the snapshot table. After successfully setting the
severity level, the snapshot table and its related objects will
contain valid data as long as the snapshot table is in the inUse
state.
          
ALCATEL NOTE:
   SUPPORT: YES   INSRVMOD: YES   RANGE: 1-5
   PERSIST: NO    DEFVALUE: NA    UNITS: -

Context

MIB
ASAM-ALARM-MIB
OID
.1.3.6.1.4.1.637.61.1.3.19
Type
scalar
Access
readwrite
Status
mandatory
Parent
asamAlarmMIB
Siblings
67

Syntax

AsamAlarmSeverityType
Source
AsamAlarmSeverityType
Base type
Enumeration

Values & Constraints

Type Values
0alllevel
1indeterminate
2warning
3minor
4major
5critical
6ignore

Related Objects