fsY1564SlaStepLoadRate

ARICENT-Y1564-CFG-MIB · .1.3.6.1.4.1.29601.2.88.2.1.1.8

Object

column r/w Integer32
This object specifies the step load rate of the step load CIR 
(Committed Information Rate) configuration test. If no 
value is provided, 25% of CIR is sent first,followed by 
50% of CIR and so on; the complete CIR is generated  in 4
steps. For eg, If step load rate is configured as 10, CIR test will 
be done with traffic rate incremented as 10% for each and
every step.

Context

MIB
ARICENT-Y1564-CFG-MIB
OID
.1.3.6.1.4.1.29601.2.88.2.1.1.8
Type
column
Access
readwrite
Status
current
Parent
fsY1564SlaEntry
Table
fsY1564SlaTable
Siblings
21

Syntax

Integer32

Values & Constraints

Object Constraints
range: 10-100

Related Objects

Sibling Objects