fsPtpPortSynclimit
ARICENT-PTP-MIB ·
.1.3.6.1.4.1.29601.2.45.1.7.1.1.11
Object
This specifies the maximum clock offset value before
PTP attempts to resynchronize. The range of this object
should be 50 - 1000000000 nanoseconds
The time interval field represents the values in scalednanoseconds.
The scalednanoseconds member is the time interval expressed in
units of nanoseconds and multiplied by 2^16.
Positive or negative time intervals outside the maximum range of
this data type shall be encoded as the largest positive and
negative values of this data type, respectively. For example, 2.5
nanoseconds will be expressed as 2.5 * 2^16 and the value
converted to hexadecimal will obviously evolve to
0000 0000 0002 8000 base 16.
Context
- MIB
- ARICENT-PTP-MIB
- OID
.1.3.6.1.4.1.29601.2.45.1.7.1.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- fsPtpPortConfigDataSetEntry
Syntax
SNMPv2-TCDisplayString
Values & Constraints
No enumerated values or constraints recorded.