fsIssuTraceOption

ARICENT-ISSU-MIB · .1.3.6.1.4.1.29601.2.103.1.14

Object

scalar r/w SNMPv2-SMIInteger32
This object enables tracing in the selected
Issu Management  module.
          
A 32 bit integer is used to store the Tracing level in the 
specified module.
Different Tracing Levels -
          
BIT 0 - Init and Shutdown Traces
BIT 1 - Management Traces
BIT 2 - All Failure Traces
BIT 3 - Control Plane traces.
BIT 4 - Critical Traces
          
Various combinations of levels are allowed.
          
For example if the bits 0 and 1 are set, then the Trace
Statements related to Init-Shutdown and management
will be printed.
          
if the bit value is 3 then state machine transitions and 
ISSU feature  related traces will be printed.
          
The user has to enter the corresponding INTEGER VALUE for the
bits set. For example if bits 0 and 1 are set then user has to
set the value 3.

Context

MIB
ARICENT-ISSU-MIB
OID
.1.3.6.1.4.1.29601.2.103.1.14
Type
scalar
Access
readwrite
Status
current
Parent
fsIssuSystem
Siblings
16

Syntax

SNMPv2-SMIInteger32
Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects