fsErpsRingConfigHoldOffTime

ARICENT-ERPS-MIB · .1.3.6.1.4.1.29601.2.40.2.3.1.1

Object

column r/w milliseconds Unsigned32
This object is used to configure the period for the hold-off timer 
of this ring.  
              
Hold-Off timer will be started when a new defect (SF) is received for 
this ring.  This defect will not be given as local SF to ERP control 
process until Hold-Off timer expires.
              
When the Hold-Off timer expires and if a local defect still exists, it
will be given as local SF to the ERPS control process of this ring.
              
The configured value of this timer is applicable only from the next
start/re-start of the timer.
              
The Hold-Off timer has a period from 0 to 1 hour, configurable in units 
of 1 milliseconds. For example, to configure Hold-Off Time as 5 seconds, 
configure the value as 5000. Default value of Hold-Off timer is 0

Context

MIB
ARICENT-ERPS-MIB
OID
.1.3.6.1.4.1.29601.2.40.2.3.1.1
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
fsErpsRingConfigEntry
Table
fsErpsRingConfigTable
Siblings
16

Syntax

milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 0-3600000

Related Objects