fsMIY1731MepLbmTTL
ARICENT-ECFM-Y1731-MI-MIB ·
.1.3.6.1.4.1.29601.2.7.1.2.4.1.133
Object
column
r/w
Unsigned32
This object specifies the time-to-live(TTL) value to be used in the
MPLS outer label header when loopback connectivity verification (ping)
or diagnostic tests has to be performed to a MEP/MIP in the MPLS-TP
network.
By default TTL value will be 255.
If the user sets a particular value, then that TTL will be set and
carried in LBM packets.
When performing loopback connectivity verification (ping) or diagnostic
tests to a MIP, this object MUST be set to an appropriate TTL value
needed to reach the MIP.
For MIP, this must be configured in conjunction with
fsMIY1731MepTransmitLbmDestType as mipid(3), fsMIY1731MepLbmIcc,
fsMIY1731MepLbmNodeId, fsMIY1731MepLbmIfNum.
For MEP, this must be configured in conjunction with
fsMIY1731MepTransmitLbmDestType as mepid(1) and
fsMIY1731MepTransmitLbmDestMepId.
Context
- MIB
- ARICENT-ECFM-Y1731-MI-MIB
- OID
.1.3.6.1.4.1.29601.2.7.1.2.4.1.133- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- fsMIY1731MepEntry
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-255