fsBfdGblReqMinRxIntvl

ARICENT-BFD-MIB · .1.3.6.1.4.1.29601.2.53.1.6

Object

scalar r/w BFD-TC-STD-MIBBfdIntervalTC
This object specifies the minimum interval, in microseconds, 
between received BFD Control packets the local system is capable 
of supporting. This value will serve as the default receive
interval for all BFD session entries during session entry creation,
in the absence of a per-session required receive interval being 
configured for each session entry. Modification of this object will
thereon not be reflected to the individual session enteries.
(Modification of the receive interval for individual 
 session enteries should be done using the object
'bfdSessReqMinRxInterval' in the session table.) 
The modified value of this object will be used
only for the session enteries created after modification.
The default required receive interval is 1 second.

Context

MIB
ARICENT-BFD-MIB
OID
.1.3.6.1.4.1.29601.2.53.1.6
Type
scalar
Access
readwrite
Status
current
Parent
fsBfdGlobals
Siblings
11

Syntax

BFD-TC-STD-MIBBfdIntervalTC
Source
BFD-TC-STD-MIBBfdIntervalTC
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Related Objects

Sibling Objects