brzaccVLAdaptiveModulationAlgorithm
ALVARION-DOT11-WLAN-MIB ·
.1.3.6.1.4.1.12394.1.1.10.9.10
Object
scalar
r/w
Enumeration
Applicable to all units with HW version C or higher. Defines the adaptive modulation algorithm used by the unit.
Context
- MIB
- ALVARION-DOT11-WLAN-MIB
- OID
.1.3.6.1.4.1.12394.1.1.10.9.10- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- brzaccVLAdaptiveModulationParams
- Siblings
- 10
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | adaptiveModulation |
2 | statisticsBasedRateControl |
255 | na |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| brzaccVLAdaptiveModulationAlgorithmOption Applicable to all units.
Enables/disables the adaptive modulation level decision mechanism. | scalar | Enumeration | .1.3.6.1.4.1.12394.1.1.10.9.1 |
| brzaccVLAdaptiveModulationRetriesOnLowerModulations Applicable to all units with HW version C or higher.
It allows retransmissions at lower modulation levels. | scalar | Enumeration | .1.3.6.1.4.1.12394.1.1.10.9.11 |
| brzaccVLAdaptiveModulationRTSDurationMode Applicable to all units with HW version C or higher.
It defines the mode to calculate the value for RTS duration field. | scalar | Enumeration | .1.3.6.1.4.1.12394.1.1.10.9.12 |
| brzaccVLSoftwareRetrySupport Applicable to all units.
Read-only for units with version 2.0.
Not applicable for units with SW version 3.0 and higher.
The status of the Software Retry mechanism.
Enabled whe… | scalar | Enumeration | .1.3.6.1.4.1.12394.1.1.10.9.2 |
| brzaccVLNumOfSoftwareRetries Applicable to all units.
Read-only for units with version 2.0.
Not applicable for units with SW version 3.0 and higher.
The maximum number of times to use the Software Retry me… | scalar | Enumeration | .1.3.6.1.4.1.12394.1.1.10.9.3 |
| brzaccVLMinIntervalBetweenAdaptiveModulationAlgorithmMessages Applicable all units.
The minimum interval between two consecutive AU/BU to SU/RB messages.
Range: 1 to 3600 (Sec). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12394.1.1.10.9.4 |
| brzaccVLAdaptiveModulationDecisionThresholds Applicable to all units.
Defines the setting of thresholds for the rate decision algorithm.
high (2) should typically be used when the SNR is lower than 13dB. | scalar | Enumeration | .1.3.6.1.4.1.12394.1.1.10.9.5 |
| brzaccVLAdaptiveModulationHistorySize Applicable to all units with HW version C or higher.
This value is used to compute the transmission time.
Not used in version 6.0 and higher. | scalar | Integer32 | .1.3.6.1.4.1.12394.1.1.10.9.7 |
| brzaccVLAdaptiveModulationPacketThresholdToTestUpRate Applicable to all units with HW version C or higher.
When the number of transmitted frames exceeds this number
the upper modulations will be tested. | scalar | Integer32 | .1.3.6.1.4.1.12394.1.1.10.9.8 |
| brzaccVLAdaptiveModulationPacketNoOnUpperRate Applicable to all units with HW version C or higher.
The number of frames used on upper modulations. | scalar | Integer32 | .1.3.6.1.4.1.12394.1.1.10.9.9 |