aluSecLogEventControl
ALU-SECURITY-MIB ·
.1.3.6.1.4.1.6527.6.1.2.2.17.5.3.1.4
Object
column
r/w
Enumeration
Suppress/Throttle the generation of an event or event type. - Each event can individually be suppressed. - Throttling or disabling event control must be done at the event-type level by setting aluSecLogEventControl using an Event-Id of '0'. - Suppression of an entire event-type can also be done by setting aluSecLogEventControl with an Event-Id og '0'.
Context
- MIB
- ALU-SECURITY-MIB
- OID
.1.3.6.1.4.1.6527.6.1.2.2.17.5.3.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- aluSecLogEventEntry
- Table
- aluSecLogEventTable
- Siblings
- 3
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | off |
2 | throttled |
3 | suppressed |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| aluSecLogEventType The value of the object aluSecLogEventType specifies
the type/category of the event. | column | Enumeration | .1.3.6.1.4.1.6527.6.1.2.2.17.5.3.1.1 |
| aluSecLogEventId The value of the object aluSecLogEventId specifies
the unique id of the event within the Event Type/Category.
An Event-Id of 0 is used to set settings at the Event Type level.
The… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.6.1.2.2.17.5.3.1.2 |
| aluSecLogEventName The value of the object aluSecLogEventName
specifies the name of the Log Event. This value is read-only. | column | TIMETRA-TC-MIBTNamedItemOrEmpty | .1.3.6.1.4.1.6527.6.1.2.2.17.5.3.1.3 |