fanAndPsRpsConnectionStatus
ALLIEDTELESYN-MIB ·
.1.3.6.1.4.1.207.8.4.4.3.1.1
Object
scalar
mandatory
Enumeration
The status of the Redundant Power Supply (RPS) connection, ie, whether an RPS is actually connected or not, regardless of whether the RPS is on or not. not-supported means that an RPS is not supported in this hardware platform, connected means that the RPS is connected, not-connected means that the RPS is not connected, and not-monitoring means that the status of the RPS is not being monitored presently. RPS monitoring can be turned on via the variable fanAndPsRpsMonitoringStatus, or by the command SET SYSTEM RPSMONITOR=ON.
Context
- MIB
- ALLIEDTELESYN-MIB
- OID
.1.3.6.1.4.1.207.8.4.4.3.1.1- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- fanAndPs
- Siblings
- 11
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | non-supported |
1 | connected |
2 | not-connected |
3 | not-monitoring |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fanAndPsMainMonitoringStatus mandatory The current status of main power supply monitoring. The
monitoring of the main power supply and its fan is always
enabled by those systems that support it. Systems which do
not su… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.10 |
| fanAndPsPsuStatusTable mandatory The table of AT8948 fanAndPsPsuStatusTable. Each entry in the table
represents the status of one of the power supplies in AT8948 system.
Each power supply has its own board ID. | table | - | .1.3.6.1.4.1.207.8.4.4.3.1.11 |
| fanAndPsAccelFanStatus mandatory The status of the accelerator card fans. Non-supported means this
device does not support monitoring of the accelerator card fans. | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.12 |
| fanAndPsMainPSUStatus mandatory The status of the main Power Supply. on means that the power supply is present
and fully operational. off means that the power supply is totally off (and
obviously only applies to… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.2 |
| fanAndPsRedundantPSUStatus mandatory The status of the redundant Power Supply. non-supported means
this device does not support redundant power supplies, on
means that the redundant power supply is connected and able… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.3 |
| fanAndPsRpsMonitoringStatus mandatory The current status of redundant power supply monitoring. The
monitoring of the redundant power supply and its fan must be
enabled by command or by setting this variable to on. The… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.4 |
| fanAndPsMainFanStatus mandatory The status of the main Power Supply fan. non-supported means that this
device does not support monitoring on the main power supply fan, or that
there is no main power supply fan. … | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.5 |
| fanAndPsRedundantFanStatus mandatory The status of the redundant Power Supply Fan. non-supported means
this device does not support redundant power supplies, ok
means that the redundant power supply fan is running, n… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.6 |
| fanAndPsTemperatureStatus mandatory The status of temperature in this device. ok means that the
device is not capable of monitoring temperature or that the
temperature is OK, not-ok means that the temperature is bei… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.7 |
| fanAndPsFanTrayPresent mandatory The status of the presence of the fan tray in this system. Systems
which do not support a fan tray return the value non-supported. Upon
removal of the fan tray there is a short pe… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.8 |
| fanAndPsFanTrayStatus mandatory The status of the fan tray in this system. Systems which do not support
a fan tray return the value non-supported. The value ok is returned if all fans
in the fan tray are running… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.9 |