fanAndPsRpsConnectionStatus

ALLIEDTELESYN-MIB · .1.3.6.1.4.1.207.8.4.4.3.1.1

Object

scalar mandatory Enumeration
The status of the Redundant Power Supply (RPS) connection,
ie, whether an RPS is actually connected or not, regardless
of whether the RPS is on or not. not-supported means that an
RPS is not supported in this hardware platform, connected
means that the RPS is connected, not-connected means that the
RPS is not connected, and not-monitoring means that the status
of the RPS is not being monitored presently. RPS monitoring can
be turned on via the variable fanAndPsRpsMonitoringStatus, or
by the command SET SYSTEM RPSMONITOR=ON.

Context

MIB
ALLIEDTELESYN-MIB
OID
.1.3.6.1.4.1.207.8.4.4.3.1.1
Type
scalar
Access
readonly
Status
mandatory
Parent
fanAndPs
Siblings
11

Syntax

Enumeration

Values & Constraints

Enumerated Values
0non-supported
1connected
2not-connected
3not-monitoring

Related Objects

Sibling Objects