pmRxPwr24HRlts1Threshold
ALFOPLUS-SIAE-MIB ·
.1.3.6.1.4.1.3373.25.12.3
Object
Number of seconds within a day to set pmRxPwrTpClass24HRlts1Alarm (zero value disables the alarm).
Context
- MIB
- ALFOPLUS-SIAE-MIB
- OID
.1.3.6.1.4.1.3373.25.12.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- pmRxPwr
- Siblings
- 19
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pmRxPwrCounterTable Table with PmRxPwr records: one record for 1+0 configuration and two
record for 1+1 configuration. | table | - | .1.3.6.1.4.1.3373.25.12.1 |
| pmRxPwr15MRlts4Threshold Number of seconds within 15 minutes to set
pmRxPwrTpClass15MRlts4Alarm (zero value disables the alarm). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.25.12.10 |
| pmRxPwrRlt1Threshold Received Power Level Threshold 1 (dBm value). | scalar | Integer32 | .1.3.6.1.4.1.3373.25.12.11 |
| pmRxPwrRlt2Threshold Received Power Level Threshold 2 (dBm value). | scalar | Integer32 | .1.3.6.1.4.1.3373.25.12.12 |
| pmRxPwrRlt3Threshold Received Power Level Threshold 3 (dBm value). | scalar | Integer32 | .1.3.6.1.4.1.3373.25.12.13 |
| pmRxPwrRlt4Threshold Received Power Level Threshold 4 (dBm value). | scalar | Integer32 | .1.3.6.1.4.1.3373.25.12.14 |
| pmRxPwrTpClass15MRltsAlarmSeverityCode Define the severity associated to the pmRxPwrTpClass15MRltsAlarm and
enables/disables the trap generation on status change event. | scalar | Enumeration | .1.3.6.1.4.1.3373.25.12.15 |
| pmRxPwrTpClass24HRltsAlarmSeverityCode Define the severity associated to the pmRxPwrTpClass24HRltsAlarm and
enables/disables the trap generation on status change event. | scalar | Enumeration | .1.3.6.1.4.1.3373.25.12.16 |
| pmRxPwr24HRlts5Threshold Number of seconds within a day to set pmRxPwrTpClass24HRlts5Alarm
(zero value disables the alarm). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.25.12.17 |
| pmRxPwr15MRlts5Threshold Number of seconds within 15 minutes to set
pmRxPwrTpClass15MRlts5Alarm (zero value disables the alarm). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.25.12.18 |
| pmRxPwrRlt5Threshold Received Power Level Threshold 5 (dBm value). | scalar | Integer32 | .1.3.6.1.4.1.3373.25.12.19 |
| pmRxPwrTpClassTable Table with PmRxPwrTpClass records: one record for 1+0 configuration
and two record for 1+1 configuration. | table | - | .1.3.6.1.4.1.3373.25.12.2 |
| pmRxPwrRlt5AdaptThreshold Value to be added received Power Level Threshold when the microwave is in
adaptive capacity; range 0 to 20 | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.25.12.20 |
| pmRxPwr24HRlts2Threshold Number of seconds within a day to set pmRxPwrTpClass24HRlts2Alarm
(zero value disables the alarm). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.25.12.4 |
| pmRxPwr24HRlts3Threshold Number of seconds within a day to set pmRxPwrTpClass24HRlts3Alarm
(zero value disables the alarm). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.25.12.5 |
| pmRxPwr24HRlts4Threshold Number of seconds within a day to set pmRxPwrTpClass24HRlts4Alarm
(zero value disables the alarm). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.25.12.6 |
| pmRxPwr15MRlts1Threshold Number of seconds within 15 minutes to set
pmRxPwrTpClass15MRlts1Alarm (zero value disables the alarm). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.25.12.7 |
| pmRxPwr15MRlts2Threshold Number of seconds within 15 minutes to set
pmRxPwrTpClass15MRlts2Alarm (zero value disables the alarm). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.25.12.8 |
| pmRxPwr15MRlts3Threshold Number of seconds within 15 minutes to set
pmRxPwrTpClass15MRlts3Alarm (zero value disables the alarm). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.25.12.9 |