svcEndPointRevertTimeCountDn
ALCATEL-ENT1-TIMETRA-SERV-MIB ·
.1.3.6.1.4.1.6527.3.1.2.4.2.19.1.16
Object
column
seconds Integer32
The value of svcEndPointRevertTimeCountDn indicates the timer
count down before reverting back to the primary spoke-sdp
defined on this service endpoint, after having failed over to
a backup spoke-sdp.
This timer count down begins after primary Spoke SDP becomes
operational.
The value of -1 indicates when revert is not-applicable.
Context
- MIB
- ALCATEL-ENT1-TIMETRA-SERV-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.4.2.19.1.16- Type
- column
- Access
- readonly
- Status
- current
- Units
- seconds
- Parent
- svcEndPointEntry
Syntax
seconds Integer32
Values & Constraints
Object Constraints
range: -1-600