alcatelIND1IsisSpbProtocolSpfSecondWait

ALCATEL-ENT1-ISIS-SPB-MIB · .1.3.6.1.4.1.6486.801.1.2.1.10.17.1.1.2.3

Object

scalar r/w milliseconds Unsigned32
The value of alcatelIND1IsisSpbProtocolSpfSecondWait defines the hold time
between the first and second SPF calculation (in milliseconds).
          
Subsequent SPF runs will occur at exponentially increasing
intervals of spf-second-wait i.e. if spf-second-wait is 1000,
then the next SPF will run after 2000 msec, the next one at
4000 msec etc until it is capped off at spf-wait value.
          
The SPF interval will stay at spf-wait value until there are no
more SPF runs scheduled in that interval. After a full interval
without any SPF runs, the SPF interval will drop back to
spf-initial-wait.

Context

MIB
ALCATEL-ENT1-ISIS-SPB-MIB
OID
.1.3.6.1.4.1.6486.801.1.2.1.10.17.1.1.2.3
Type
scalar
Access
readwrite
Status
current
Units
milliseconds
Parent
alcatelIND1IsisSpbProtocolConfig
Siblings
7

Syntax

milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 1-100000

Related Objects