alaBfdIntfReqMinRxInterval

ALCATEL-ENT1-BFD-MIB · .1.3.6.1.4.1.6486.801.1.2.1.45.1.1.2.1.6

Object

column r/w AlaBfdInterval
The Minimum Rx interval at which packets can be received for BFD sessions on
this interface. The default value for this object is derived from the value of
alaBfdGlobalRxInterval.

Context

MIB
ALCATEL-ENT1-BFD-MIB
OID
.1.3.6.1.4.1.6486.801.1.2.1.45.1.1.2.1.6
Type
column
Access
readwrite
Status
current
Parent
alaBfdIntfEntry
Table
alaBfdIntfTable
Siblings
12

Syntax

AlaBfdInterval
Source
AlaBfdInterval
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Related Objects

Sibling Objects