oduSectionConfigSignalDegradeThres
ADVA-MIB ·
.1.3.6.1.4.1.2544.2.5.4.2.2.1.1.1
Object
column
r/w
% Integer32
Threshold for ODU SM-SD alarm (threshold level 0..100%, default value 15 %. Ref. table 24/G.7710.
Context
- MIB
- ADVA-MIB
- OID
.1.3.6.1.4.1.2544.2.5.4.2.2.1.1.1- Type
- column
- Access
- readwrite
- Status
- current
- Units
- %
- Parent
- oduSectionConfigEntry
- Table
- oduSectionConfigTable
- Siblings
- 6
Syntax
% Integer32
Values & Constraints
Object Constraints
range: -2147483648--2147483648
range: 1-100
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| oduSectionConfigSignalDegradePeriod Measuring period for ODU SM-SD alarm: 2..10 sec) (bursty)
Ref. table 24/G.7710. Default value: 7. | column | s Unsigned32 | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.2 |
| oduSectionConfigTraceExpected Expected SAPI part of the ODU trace (15 character). NULL TRACE implies that no trace comparison is made. | column | OctetString | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.3 |
| oduSectionConfigTraceTransmitSapi The transmitted SAPI part of the ODU trace (15 character) | column | OctetString | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.4 |
| oduSectionConfigTraceTransmitDapi The transmitted DAPI part of the ODU trace (15 character) | column | OctetString | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.5 |
| oduSectionConfigTraceTransmitOpsp The transmitted Operator Specific part of the ODU trace (32 character) | column | OctetString | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.6 |
| oduSectionConfigTimMode Detection of TIM-ODU Condition can be configured | column | TimMode | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.7 |