oduSectionConfigSignalDegradePeriod
ADVA-MIB ·
.1.3.6.1.4.1.2544.2.5.4.2.2.1.1.2
Object
column
r/w
s Unsigned32
Measuring period for ODU SM-SD alarm: 2..10 sec) (bursty) Ref. table 24/G.7710. Default value: 7.
Context
- MIB
- ADVA-MIB
- OID
.1.3.6.1.4.1.2544.2.5.4.2.2.1.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Units
- s
- Parent
- oduSectionConfigEntry
- Table
- oduSectionConfigTable
- Siblings
- 6
Syntax
s Unsigned32
Values & Constraints
Object Constraints
range: 2-10
range: 4294967295-4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| oduSectionConfigSignalDegradeThres Threshold for ODU SM-SD alarm (threshold level 0..100%,
default value 15 %. Ref. table 24/G.7710. | column | % Integer32 | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.1 |
| oduSectionConfigTraceExpected Expected SAPI part of the ODU trace (15 character). NULL TRACE implies that no trace comparison is made. | column | OctetString | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.3 |
| oduSectionConfigTraceTransmitSapi The transmitted SAPI part of the ODU trace (15 character) | column | OctetString | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.4 |
| oduSectionConfigTraceTransmitDapi The transmitted DAPI part of the ODU trace (15 character) | column | OctetString | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.5 |
| oduSectionConfigTraceTransmitOpsp The transmitted Operator Specific part of the ODU trace (32 character) | column | OctetString | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.6 |
| oduSectionConfigTimMode Detection of TIM-ODU Condition can be configured | column | TimMode | .1.3.6.1.4.1.2544.2.5.4.2.2.1.1.7 |