adTASysCtrlPowerShedCountDown
ADTRAN-TACONTROLER-PRODUCT-MIB ·
.1.3.6.1.4.1.664.5.63.70.31
Object
scalar
Integer32
Countdown timer indicating the number of minutes remaining until Power Shedding is Activated or until Power Shedding is Deactivated. If Power Shedding is ENABLED and the CountDown is zero (0), it means the countdown time has expired and Power Shedding is taking place. If Power Shedding is DISABLED and the CountDown is zero (0), it means Power Shedding is Inactive or Off.
Context
- MIB
- ADTRAN-TACONTROLER-PRODUCT-MIB
- OID
.1.3.6.1.4.1.664.5.63.70.31- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- adTaSysCtrlPowerShed
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-1440