adGenVdsl2ScStatusUsHlog

ADTRAN-GENVDSL2-LINE-MIB · .1.3.6.1.4.1.664.5.65.1.2.7.1.10

Object

column 0.1 dB Integer32
Upstream channel transfer function (HLOG) per sub-carrier number. The HLOG
ranges from -96.3 to +6.0 dB with 0.1 dB steps. A special value of
-963 indicates that no measurement could be done for the
subcarrier because it is out of the passband or that the noise
PSD is out of range to be represented.

Context

MIB
ADTRAN-GENVDSL2-LINE-MIB
OID
.1.3.6.1.4.1.664.5.65.1.2.7.1.10
Type
column
Access
readonly
Status
current
Units
0.1 dB
Parent
adGenVdsl2ScStatusEntry
Table
adGenVdsl2ScStatusTable
Siblings
10

Syntax

0.1 dB Integer32

Values & Constraints

Object Constraints
range: -963-60

Related Objects