adGenVdsl2ScStatusUsHlog
ADTRAN-GENVDSL2-LINE-MIB ·
.1.3.6.1.4.1.664.5.65.1.2.7.1.10
Object
column
0.1 dB Integer32
Upstream channel transfer function (HLOG) per sub-carrier number. The HLOG ranges from -96.3 to +6.0 dB with 0.1 dB steps. A special value of -963 indicates that no measurement could be done for the subcarrier because it is out of the passband or that the noise PSD is out of range to be represented.
Context
- MIB
- ADTRAN-GENVDSL2-LINE-MIB
- OID
.1.3.6.1.4.1.664.5.65.1.2.7.1.10- Type
- column
- Access
- readonly
- Status
- current
- Units
- 0.1 dB
- Parent
- adGenVdsl2ScStatusEntry
Syntax
0.1 dB Integer32
Values & Constraints
Object Constraints
range: -963-60