adGenTA8xxRelayTest
ADTRAN-GENTA8XX-MIB ·
.1.3.6.1.4.1.664.5.69.2.5.1.3
Object
scalar
r/w
Enumeration
Enable or Disable the testing of the alarm relays. When disabled the Alarm Relays are activated/deactivated based on system alarms. When enabled the Alarm relays can be controlled with adGenTA8xxToggleCriticalRelay, adGenTA8xxToggleMajorRelay, and adGenTA8xxToggleMinorRelay.
Context
- MIB
- ADTRAN-GENTA8XX-MIB
- OID
.1.3.6.1.4.1.664.5.69.2.5.1.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- adGenTA8xxTstScalars
- Siblings
- 5
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | disable |
2 | enable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| adGenTA8xxResetTests A Set operation with value of 1 will reset all loopbacks currently in effect. | scalar | Enumeration | .1.3.6.1.4.1.664.5.69.2.5.1.1 |
| adGenTA8xxTestTimeout Indicates the amount of time that a test will remain in
effect before self-release occurs. | scalar | Enumeration | .1.3.6.1.4.1.664.5.69.2.5.1.2 |
| adGenTA8xxTestCriticalRelay Set the Critical Alarm Relay if adGenTA8xxRelayTest is enabled.
A read returns last value set. | scalar | Enumeration | .1.3.6.1.4.1.664.5.69.2.5.1.4 |
| adGenTA8xxTestMajorRelay Set the Major Alarm Relay if adGenTA8xxRelayTest is enabled.
A read returns last value set. | scalar | Enumeration | .1.3.6.1.4.1.664.5.69.2.5.1.5 |
| adGenTA8xxTestMinorRelay Set the Minor Alarm Relay if adGenTA8xxRelayTest is enabled.
A read returns last value set. | scalar | Enumeration | .1.3.6.1.4.1.664.5.69.2.5.1.6 |