adGenFxoInterfaceCWCIdAckGenDelay
ADTRAN-GENFXO-MIB ·
.1.3.6.1.4.1.664.5.70.38.1.2.1.1.10
Object
column
r/w
Unsigned32
Use to set the Call-Waiting Caller-ID ACK generation delay.
Context
- MIB
- ADTRAN-GENFXO-MIB
- OID
.1.3.6.1.4.1.664.5.70.38.1.2.1.1.10- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- adGenFxoInterfaceProvEntry
- Table
- adGenFxoInterfaceProvTable
- Siblings
- 15
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-100
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| adGenFxoInterfaceLastErrorString The reason for the last error that occured while accessing an entry in
the FXO Interface Prov Table. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.1 |
| adGenFxoInterfaceCWCIdAckGenEnable Use to enable/disable Caller-ID ACK generation during Call-Waiting
interval. | column | Enumeration | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.11 |
| adGenFxoInterfaceTargetFxsLocation Use to connect FXO interface to an FXS interface. | column | AdGenFxoInterfaceFxsLocation | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.12 |
| adGenFxoInterfaceRingTripMode Use to set the ring-trip mode of the interface.
1 = normal Use a normal off-hook to trip ringing voltage.
2 = forced Force a ring-ground on loop to sink ringing curr… | column | Enumeration | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.13 |
| adGenFxoInterfaceRingTripDuration Use to set duration of the ring-ground interval in 'forced' ring-trip mode. | column | milliseconds Unsigned32 | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.14 |
| adGenFxoInterfaceRingTripMuteInterval Use to set a delay before enabling the voice path when going off-hook, exiting
the 'forced' or 'delayed' ring-trip modes.
Valid values are <0,20-400> ('0' to disable). | column | milliseconds Unsigned32 | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.15 |
| adGenFxoCircuitIdentifier The circuit identifier string for the fxo port. | column | OctetString | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.16 |
| adGenFxoInterfaceSignalingMode Use to set signaling mode of the 2-Wire interface.
1 = loopStart Loop-Start signaling.
2 = groundStart Ground-Start signaling.
3 = tr08sp TR-08 Single Party signaling… | column | Enumeration | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.2 |
| adGenFxoInterfaceTxGain Set gain from the line (A/D). | column | 0.1dB SNMPv2-SMIInteger32 | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.3 |
| adGenFxoInterfaceMinTxGain Range of adGenFxoInterfaceTxGain varies by product. Retrieve minimum
valid Tx Gain value for use in range checking. | column | 0.1dB SNMPv2-SMIInteger32 | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.4 |
| adGenFxoInterfaceMaxTxGain Range of adGenFxoInterfaceTxGain varies by product. Retrieve maximum
valid Tx Gain value for use in range checking. | column | 0.1dB SNMPv2-SMIInteger32 | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.5 |
| adGenFxoInterfaceRxGain Set gain toward the line (D/A). | column | 0.1dB SNMPv2-SMIInteger32 | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.6 |
| adGenFxoInterfaceMinRxGain Range of adGenFxoInterfaceTxGain varies by product. Retrieve minimum
valid Rx Gain value for use in range checking. | column | 0.1dB SNMPv2-SMIInteger32 | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.7 |
| adGenFxoInterfaceMaxRxGain Range of adGenFxoInterfaceTxGain varies by product. Retrieve maximum
valid Rx Gain value for use in range checking. | column | 0.1dB SNMPv2-SMIInteger32 | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.8 |
| adGenFxoInterfaceImpedance Use to set the terminating impedance of the interface.
1 = z600r 600 Ohms.
2 = z900z 900 Ohms + 2.16 uF.
3 = z1 220 + ( 820 // 115nF).
4 = z2 … | column | Enumeration | .1.3.6.1.4.1.664.5.70.38.1.2.1.1.9 |