adGenImaAtmGroupCommonProvDhcpCircuitIdFormat

ADTRAN-GENERIC-IMA-MIB · .1.3.6.1.4.1.664.5.67.1.25.1.2.1.1

Object

column r/w OctetString
Used to provision the format of the circuit ID string. This string is used 
to provision DHCP Option 82 sub-option 1 cirduit id that will be added to 
the DHCP messages.
TR-101 states that the format of the circuit ID 
should be user defineable. The string may contain both fixed 
static string elements specified by the user and also variable 
and fixed length elements which are populated by the network 
element. Variable length elements are specified by enclosing 
the names of the variables with a dollar sign '$'. For instance, 
a user could specify a circuit id string as follows:
'TA1148-$accessnodeid$ Port: $port$ $vpi$/$vci$'
              
which would expand to
'TA1148-TID Port: 1 0/35'.
              
In this implementation, the access-node-id is equivalent to the
system's provisioned TID or SNMP sysName. If this string is
provisioned zero-length, then the default format is used.
The total length of the expanded string MUST NOT exceed
63 characters.
              
Variables include (but are not limited to) the following:
    Variable Name               Character Length
    accessnodeid                Varies
    slot                        3
    port                        3
    vpi                         4
    vci                         5
              
If a user defined circuit ID is not desired, this object can
be set to simply 'default' and the default format described in
TR-101 will be used:
              
access-node-id atm slot/port:vpi.vci

Context

MIB
ADTRAN-GENERIC-IMA-MIB
OID
.1.3.6.1.4.1.664.5.67.1.25.1.2.1.1
Type
column
Access
readwrite
Status
current
Parent
adGenImaAtmGroupCommonProvEntry
Table
adGenImaAtmGroupCommonProvTable

Syntax

OctetString

Values & Constraints

Object Constraints
range: 0-63

Related Objects

Indexes