adGenFrGroupEntry
ADTRAN-GEN-FRAME-RELAY-MIB ·
.1.3.6.1.4.1.664.5.70.29.1.1.2.1
Object
row
The Frame Relay Group provisioning and status table entry. To
create a frame relay group, the following procedures are used:
(1) The management application creates Frame Relay Group
entry in the adGenFrGroupTable by setting the
adGenFrGroupRowStatus to createAndWait(5).
This may fail for the following reasons which are reported
through the adGenFrSlotGroupLastCreateError object:
- The selected ifIndex specifies an invalid interface
- The selected ifIndex is already in use by another Frame
Relay Group
Otherwise, upon successful creation of the row, the group
is reserved and a corresponding row (identical ifIndex)
in the frMgtVcSigTable is created.
(2) The manager sets other provisioning rows in the
adGenFrGroupTable and the frMgtVCSigTable that are
appropriate for the service that is to be provided.
(3) Connect a frame relay link to the group to specify which
interface is to provide service to the group. See the
adGenFrLinkTable description for more information.
(4) If no detectable errors or conflicts in the group
provisioning is detected, the adGenFrSlotGroupLastCreateError
object will contain an empty (zero length) string and
and can be enabled by setting adGenFrGroupRowStatus to active(1).
(*) Signaling errors (if enabled) and any provisioning failures
after setting the adGenFrGroupRowStatus to active(1) can be
detected by examining the ifTable's ifOperStatus object. If
this value is not up(1), the adGenFrSlotGroupLastCreateError
object will contain further diagnostic information as to the
cause of any failure.
Context
- MIB
- ADTRAN-GEN-FRAME-RELAY-MIB
- OID
.1.3.6.1.4.1.664.5.70.29.1.1.2.1- Type
- row
- Status
- current
- Parent
- adGenFrGroupTable
- Table
- adGenFrGroupTable
- Children
- 16
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| adGenFrGroupRowStatus The adGenFrGroupRowStatus object allows create, change, and
delete operations on the Frame Relay Group / Bearer Channel. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.1 |
| adGenFrGroupLmiStatusOut The number of Status messages transmitted. If the logical port
is not performing network-side or bidirectional procedures then
this object is not applicable. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.10 |
| adGenFrGroupLmiInvalidIn The number of invalid LMI messages received by this logical port. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.11 |
| adGenFrGroupLmiStatusEnqTimeouts The number of times this logical port has failed to receive a
Status Enquiry message in T392 seconds. If the logical port is
not performing network-side or bidirectional procedur… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.12 |
| adGenFrGroupLmiStatusTimeouts The number of times this logical port has failed to receive a
Status message in a polling interval (within T391 seconds). If
the logical port is not performing user-side or bidir… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.13 |
| adGenFrGroupClearCounters Writing a value of 1 will reset the interface and signaling
statistics for this logical port. | column | Enumeration | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.14 |
| adGenFrGroupClearPmHistory Writing a value of 1 will reset the interface performance
monitoring statistics/intervals for this logical port. | column | Enumeration | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.15 |
| adGenFrGroupLinkLastCreateError The reason for the last error that occurred while attempting to
create an entry in the Frame Relay Link Table (adGenFrLinkTable)
for this specific frame relay group. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.16 |
| adGenFrGroupPvcLastCreateError The reason for the last error that occurred while attempting to
create an entry in the Frame Relay PVC Table (adGenFrPVCTable)
for this specific frame relay group. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.17 |
| adGenFrGroupStatusString The reason, if any, why the why the group is not in an
operational state due to provisioning or hardware limitations. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.2 |
| adGenFrGroupAdminStatus The desired state of the frame relay group. This object
must be set to up(1) or testing(3) to enable user data
transmission on PVCs of this group and for enabling of
any signalin… | column | Enumeration | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.3 |
| adGenFrGroupLmiType The value of this object identifies the local in-channel signaling
protocol that is used for this frame relay UNI/NNI logical port. | column | Enumeration | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.5 |
| adGenFrGroupLmiStatus The value of this object identifies status of local in-channel signaling
protocol. If the signaling protocol is 'none', then this object will
report 'up'. | column | Enumeration | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.6 |
| adGenFrGroupLmiEnquiryIn The number of Status Enquiry messages received. If the logical
port is not performing network-side or bidirectional procedures
then this object is not applicable. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.7 |
| adGenFrGroupLmiEnquiryOut The number of Status Enquiry messages transmitted. If the logical
port is not performing user-side or bidirectional procedures
then this object is not applicable. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.8 |
| adGenFrGroupLmiStatusIn The number of Status messages received. If the logical port
is not performing user-side or bidirectional procedures then
this object is not applicable. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.664.5.70.29.1.1.2.1.9 |