acdAlarmCfgNumber
ACD-ALARM-MIB ·
.1.3.6.1.4.1.22420.2.1.10.1.2
Object
column
SNMPv2-SMIUnsigned32
Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.BBB.CC and is expressed in decimal, A is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8.
Context
- MIB
- ACD-ALARM-MIB
- OID
.1.3.6.1.4.1.22420.2.1.10.1.2- Type
- column
- Access
- readonly
- Status
- current
- Parent
- acdAlarmCfgEntry
- Table
- acdAlarmCfgTable
- Siblings
- 8
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| acdAlarmCfgID Unique value for each alarm. Its value ranges from 1 to
MAXINT (4 bytes). | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.22420.2.1.10.1.1 |
| acdAlarmCfgDesc This string is to describe the alarm in a readable way, e.g.:
+5Vdc Power supply fail. | column | OctetString | .1.3.6.1.4.1.22420.2.1.10.1.3 |
| acdAlarmCfgEnable This is to indicate if the alarm is reported or not. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.22420.2.1.10.1.4 |
| acdAlarmCfgSeverity Accedian Networks classifies alarms into four severity types. These types
and their associated decimal codes are, informational(0), minor(1),
major(2) and critical(3). | column | Enumeration | .1.3.6.1.4.1.22420.2.1.10.1.5 |
| acdAlarmCfgServiceAffecting This is to indicate if the alarm is service affecting or not. This
value depends on the utilization of the box. For instance in an
application where the monitoring of the traffic … | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.22420.2.1.10.1.6 |
| acdAlarmCfgExtNumber Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm… | column | OctetString | .1.3.6.1.4.1.22420.2.1.10.1.7 |
| acdAlarmCfgConditionType This is the type of alarm condition. | column | OctetString | .1.3.6.1.4.1.22420.2.1.10.1.8 |
| acdAlarmCfgAMOType This is the Alarm Maintenance Object. | column | OctetString | .1.3.6.1.4.1.22420.2.1.10.1.9 |