netEnergy
ACCUENERGY-MIB ·
.1.3.6.1.4.1.39604.1.1.1.1.2.4
Object
This is Energy NET. It can be set as primary energy or secondary energy according to user. Relationship between numerical value in the register and the real physical value is Ep=Rx/10(primary), Ep=Rx/1000(secondary)
Context
- MIB
- ACCUENERGY-MIB
- OID
.1.3.6.1.4.1.39604.1.1.1.1.2.4- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- energy
- Siblings
- 8
Syntax
RFC1155-SMIInteger32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| importEnergy mandatory This is Energy IMP.It can be set as primary energy or
secondary energy according to user. Relationship between numerical
value in the register and the real physical value is
Ep=R… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.2.1 |
| exportEnergy mandatory This is Energy EXP.It can be set as primary energy or
secondary energy according to user. Relationship between numerical
value in the register and the real physical value is
Ep=R… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.2.2 |
| totalEnergy mandatory This is Energy TOTAL.It can be set as primary energy or
secondary energy according to user. Relationship between numerical
value in the register and the real physical value is
Ep… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.2.3 |
| importReactiveEnergy mandatory This is Reactive energy IMP. It can be set as primary energy or
secondary energy according to user. Relationship between numerical
value in the register and the real physical val… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.2.5 |
| exportReactiveEnergy mandatory This is Reactive energy EXP. It can be set as primary energy or
secondary energy according to user. Relationship between numerical
value in the register and the real physical val… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.2.6 |
| totalReactiveEnergy mandatory This is Reactive energy TOTAL.It can be set as primary energy or
secondary energy according to user. Relationship between numerical
value in the register and the real physical va… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.2.7 |
| netReactiveEnergy mandatory This is Reactive energy NET.It can be set as primary energy or
secondary energy according to user. Relationship between numerical
value in the register and the real physical valu… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.2.8 |
| apparentEnergy mandatory This is Apparent energy.It can be set as primary energy or
secondary energy according to user. Relationship between numerical
value in the register and the real physical value is… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.2.9 |