demand
ACCUENERGY-MIB ·
.1.3.6.1.4.1.39604.1.1.1.1.1.8
Object
node
No description available.
Context
- MIB
- ACCUENERGY-MIB
- OID
.1.3.6.1.4.1.39604.1.1.1.1.1.8- Type
- node
- Parent
- realTimeMetering
- Siblings
- 9
- Children
- 6
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| phaseVoltage | node | - | .1.3.6.1.4.1.39604.1.1.1.1.1.1 |
| loadFeature mandatory This is Load characteristic(L/C/R).
76.0/67.0/82.0(ASCII)
Type: float | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.1.10 |
| lineVoltage | node | - | .1.3.6.1.4.1.39604.1.1.1.1.1.2 |
| currentMetering | node | - | .1.3.6.1.4.1.39604.1.1.1.1.1.3 |
| power | node | - | .1.3.6.1.4.1.39604.1.1.1.1.1.4 |
| reactivePower | node | - | .1.3.6.1.4.1.39604.1.1.1.1.1.5 |
| apparentPower | node | - | .1.3.6.1.4.1.39604.1.1.1.1.1.6 |
| powerFactor | node | - | .1.3.6.1.4.1.39604.1.1.1.1.1.7 |
| frequency mandatory This is Frequency. In primary mode,
the numerical value in the register of the meter
is equal to the real physical value.
Secondary Mode Relationship : F = Rx
Type: float | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.1.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| powerDemand mandatory This is Power demand. In primary mode,
the numerical value in the register of the meter
is equal to the real physical value.
Secondary Mode Relationship : P=Rx*(PT1/PT2)*(CT1/CT2… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.1.8.1 |
| reactivePowerDemand mandatory This is Reactive power demand. In primary mode,
the numerical value in the register of the meter
is equal to the real physical value.
Secondary Mode Relationship : P=Rx*(PT1/PT2)… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.1.8.2 |
| apparentPowerDemand mandatory This is Apparent power demand. In primary mode,
the numerical value in the register of the meter
is equal to the real physical value.
Secondary Mode Relationship : P=Rx*(PT1/PT2)… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.1.8.3 |
| phaseACurrentDemand mandatory This is Phase A current demand. In primary mode,
the numerical value in the register of the meter
is equal to the real physical value.
Secondary Mode Relationship : I=Rx*(CT1/CT2… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.1.8.4 |
| phaseBCurrentDemand mandatory This is Phase B current demand. In primary mode,
the numerical value in the register of the meter
is equal to the real physical value.
Secondary Mode Relationship : I=Rx*(CT1/CT2… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.1.8.5 |
| phaseCCurrentDemand mandatory This is Phase C current demand. In primary mode,
the numerical value in the register of the meter
is equal to the real physical value.
Secondary Mode Relationship : I=Rx*(CT1/CT2… | scalar | RFC1155-SMIInteger32 | .1.3.6.1.4.1.39604.1.1.1.1.1.8.6 |