resMainState

A3COM0304-RESILIENTLINKS · .1.3.6.1.4.1.43.10.15.1.1.4

Object

column mandatory Enumeration
Each port in a pair is constantly monitored for signs of 
failure. Failure information is used to automatically change the active port 
from main to standby or vice-versa. Each port may be in one of three states. 
Failed(1) indicates there is a loss of signal on this port. A port in this state 
cannot be active. Secondly ok(2). This state indicates that the port is capable 
of carrying traffic but is at the moment acting in the role of backup link. The 
other port in this pair will be in the Ok-and-active(3) state.
              
Ok-and-active(3) means what it says, this port is capable of carrying traffic 
and is so doing at the time this parameter has been read.

Context

MIB
A3COM0304-RESILIENTLINKS
OID
.1.3.6.1.4.1.43.10.15.1.1.4
Type
column
Access
readonly
Status
mandatory
Parent
resTableEntry
Table
resTable
Siblings
12

Syntax

Enumeration

Values & Constraints

Enumerated Values
1failed
2ok
3ok-and-active

Related Objects

Sibling Objects