a3ComQosCtrlRowStatus
A3COM-SWITCHING-SYSTEMS-QOS-MIB ·
.1.3.6.1.4.1.43.29.4.21.2.1.1.9
Object
column
mandatory
r/w
RowStatus
The status column for this control entry. This object can
be set to:
createAndGo(4)
destroy(6)
The following value may be read:
active(1)
Setting this object to createAndGo(4) creates a row in this
table.
Setting this object to destroy(6) will remove this entry.
Note that a control can only be deleted if it is not
attached to a flow or a non-flow classifier.
A side effect of deleting a control in this table
is the deletion of the corresponding rate limit entries in
the a3ComQosCtrlRateLimitTable.
Context
- MIB
- A3COM-SWITCHING-SYSTEMS-QOS-MIB
- OID
.1.3.6.1.4.1.43.29.4.21.2.1.1.9- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- a3ComQosCtrlEntry
- Table
- a3ComQosCtrlTable
- Siblings
- 8
Syntax
RowStatus
- Source
- RowStatus
- Base type
Enumeration
Values & Constraints
Type Values
1 | active |
2 | notInService |
3 | notReady |
4 | createAndGo |
5 | createAndWait |
6 | destroy |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| a3ComQosCtrlIndex mandatory A unique value for this entry. | column | Integer32 | .1.3.6.1.4.1.43.29.4.21.2.1.1.1 |
| a3ComQosCtrlName mandatory A textual name for the control. | column | OctetString | .1.3.6.1.4.1.43.29.4.21.2.1.1.2 |
| a3ComQosCtrlServiceLevel mandatory The service level for all conforming packets. | column | Enumeration | .1.3.6.1.4.1.43.29.4.21.2.1.1.3 |
| a3ComQosCtrlConformPktsLossEligible mandatory The variable indicates whether conforming packets are
loss eligible. | column | Enumeration | .1.3.6.1.4.1.43.29.4.21.2.1.1.4 |
| a3ComQosCtrlExcessPktsServiceLevel mandatory The service level of excess packets for this control. | column | Enumeration | .1.3.6.1.4.1.43.29.4.21.2.1.1.5 |
| a3ComQosCtrlExcessPktsLossEligible mandatory The variable indicates whether excess packets are
loss eligible. | column | Enumeration | .1.3.6.1.4.1.43.29.4.21.2.1.1.6 |
| a3ComQosCtrl8021pTag mandatory This indicates the tag to use on forwarded frames. | column | Enumeration | .1.3.6.1.4.1.43.29.4.21.2.1.1.7 |
| a3ComQosCtrlRateLimitType mandatory The rate limit type to use with this control.
A value of none(1) indicates that no rate limit is set for
this control.
A value of receivePort(2)… | column | Enumeration | .1.3.6.1.4.1.43.29.4.21.2.1.1.8 |