fsMIStdBfdSessDesiredMinTxInterval
ARICENT-BFD-STD-MI-MIB ·
.1.3.6.1.4.1.29601.2.54.2.1.1.24
Object
This object specifies the minimum interval, in microseconds, that the local system would like to use when transmitting BFD Control packets. The value of zero(0) is reserved, and should not be used.
Context
- MIB
- ARICENT-BFD-STD-MI-MIB
- OID
.1.3.6.1.4.1.29601.2.54.2.1.1.24- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- fsMIStdBfdSessEntry
Syntax
BFD-TC-STD-MIBBfdIntervalTC
Values & Constraints
No enumerated values or constraints recorded.