fsBfdGblReqMinRxIntvl
ARICENT-BFD-MIB ·
.1.3.6.1.4.1.29601.2.53.1.6
Object
This object specifies the minimum interval, in microseconds, between received BFD Control packets the local system is capable of supporting. This value will serve as the default receive interval for all BFD session entries during session entry creation, in the absence of a per-session required receive interval being configured for each session entry. Modification of this object will thereon not be reflected to the individual session enteries. (Modification of the receive interval for individual session enteries should be done using the object 'bfdSessReqMinRxInterval' in the session table.) The modified value of this object will be used only for the session enteries created after modification. The default required receive interval is 1 second.
Context
- MIB
- ARICENT-BFD-MIB
- OID
.1.3.6.1.4.1.29601.2.53.1.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- fsBfdGlobals
Syntax
BFD-TC-STD-MIBBfdIntervalTC
Values & Constraints
No enumerated values or constraints recorded.