fsBfdGblDesiredMinTxIntvl
ARICENT-BFD-MIB ·
.1.3.6.1.4.1.29601.2.53.1.5
Object
This object specifies the minimum interval, in microseconds, that the local system would like to use when transmitting BFD Control packets. This value will serve as the default desired transmit interval for all BFD session entries during session entry creation, in the absence of a per-session desired transmit interval being configured for each session entry. Modification of this object will thereon not be reflected to the individual session enteries. (Modification of the desired transmit interval for individual session enteries should be done using the object 'bfdSessDesiredMinTxInterval' in the session table.) The modified value of this object will be used only for the session enteries created after modification. The default desired transmit interval is 1 second.
Context
- MIB
- ARICENT-BFD-MIB
- OID
.1.3.6.1.4.1.29601.2.53.1.5- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- fsBfdGlobals
Syntax
BFD-TC-STD-MIBBfdIntervalTC
Values & Constraints
No enumerated values or constraints recorded.